Technical data
R911305038 / 01 | Rexroth VCP-Operating Concept Electric Drives and Controls | Bosch Rexroth AG 5-187
Standard Mode
Example: \This is one ASCII string\
Comment: Any string of characters enclosed between two dollar signs ($). Com-
ments can be inserted in the data set backup file at any position and
can stretch across several lines.
Example: $This is a comment$
Any number of separators (blanks, tab characters or line feed charac-
ters) can be placed between these language elements.
The above-mentioned language elements are used to create a file with
the following structure:
• Start of file identifier
• Any number of data sets
• End of file identifier
A data set consists of:
• Data set header
• Any number of data set variables
• End of data set identifier
Start of File Identifier
Key SFA
Parameter none (date and time are output by the operating device
as a comment)
Fig. 5-70: Start of file identifier
End of File Identifier
Key SFE
Parameter none
Fig. 5-71: End of file identifier
Data Set Header
Key SDK
Parameter Recipe number, data set number, data set name (as an
ASCII string), data set size in bytes, recipe version
number, write-over identifier
Fig. 5-72: Data set header
Data Set Variables
Key SDW
Parameter Offset of the variables in the recipe, variable size in
bytes, value of the variables (as a hexadecimal string)
Fig. 5-73: Data set variables