Technical data

5-182 Bosch Rexroth AG | Electric Drives and Controls Rexroth VCP-Operating Concept | R911305038 / 01
Standard Mode
If the controller changes to a different mask while a data set is being
modified, or if the external data release is canceled again before you
press the Data Release key, the buffer contents will likewise be dis-
carded.
The modified data set is not transferred to the controller automatically.
An explicit command from you or the controller is necessary first.
5.23.3 Data Set Transfer to/from Controller
You can load the data sets in the operating device to the controller.
You can also load (any changed) data sets from the controller to the
operating device. In this context, the data set transfer is always initiated
by the operating device, but only when the controller has activated the
corresponding release (Data Set Download Release bit in the Write
Coordination byte).
See chapter “Break“ on page 5-92.
See chapter “Transfer Single Data Set from Operating Device to Con-
troller“ on page 5-131.