Technical data
5-168 Bosch Rexroth AG | Electric Drives and Controls Rexroth VCP-Operating Concept | R911305038 / 01
Standard Mode
these system variable to change the settings online on the operating
device (using a configuration mask, for example).
If you do not give the operator a configuration option, the preselected
sorting settings will apply.
Sorting options for the serial message system:
0 - by priority
1 - by time of arrival (most recent first)
2 - by time of arrival (oldest first)
3 - by group
Sorting options for the parallel message system:
0 - by priority
1 - by time of arrival (most recent first)
2 - by time of arrival (oldest first)
3 - by group
5.22.5.4 Message Priority for Direct Display
The priority of a message is determined by its message number.
The higher the message number, the lower the message priority.
The value that represents the upper limit for the message number that
is to be indicated on arrival by a flashing LED or by outputting a system
message can be entered into the system parameters of the message
system.
If you enter the value 0, you will not be notified of newly arrived mes-
sages!
5.22.5.5 Printing the Message Memory
The memory contents of the serial and parallel message systems can
be printed either in full or in part.
The entire content of the message memory of the serial message sys-
tem is printed if the system variable PrintAllRep is set to the value '1'
(formatted printout) or the value '2' (full-length printout).
The entire content of the message memory of the parallel message
system is printed if you press a softkey or button linked to the system
variable PrintAllState.