Technical data

R911305038 / 01 | Rexroth VCP-Operating Concept Electric Drives and Controls | Bosch Rexroth AG 5-167
Standard Mode
The same options exist for serial and parallel messages.
Example: Complete message format:
Explanation of the message structure:
5.22.5.2 Size of Message Memory
The maximum message memory size allows management of up to
3000 message entries. As the amount of data is considerable, a high
performance level is required when sorting the messages, and during
resorting and initialization.
As you usually do not require this many entries, you can set the maxi-
mum memory size for messages as needed. The basic setting for the
message memory allows 500 entries.
When making the setting, take note that for example, you will need
about 50 pages of paper to print an entire message memory containing
3000 messages.
The message buffer is output in the message mask. You can use a
system variable to define message sorting.
5.22.5.3 Message Sorting
You can optionally display messages in the message mask according
to their time of arrival or according to their priority. The desired sorting
option can be selected when the system is programmed.
If both possible message systems are used, it is possible to select the
sorting settings separately. The settings are stored in the system vari-
ables RepmanRepSortCrit and RepmanSortCritP. You can use
No. Date Time Text 1 Variable 1 Text 2 Variable 2
1234 25 Aug
92
11:30:00 Tempera-
ture
285 °C at station 07
1234 4-digit message number
25 Aug 92 Date - is recorded when the message is detected in the operating device
11:30:00 Time - is recorded when the message is detected in the operating device
Temperature Text 1 in front of variable 1
285 value of variable 1 at the time of message generation, is stored in the op-
erating device
°C at station Text 2 between variable 1 and 2
07 value of variable 2 at the time of message generation, is stored in the op-
erating device