Technical data

5-162 Bosch Rexroth AG | Electric Drives and Controls Rexroth VCP-Operating Concept | R911305038 / 01
Standard Mode
operate in accordance with the true meaning of the standard mode
while these messages are displayed. In addition to true system errors,
various conditions and processes are also described.
This message is generated for all types of protocol and interface errors.
The error codes (CODE X) and SUBCODE (X) are protocol-specific
and are listed in the respective description in the chapter on controller
and bus connections. The connection with the communication partner
has been interrupted. RETRIES displays the number of unsuccessful
attempts to establish a connection. This number is incremented while
the device is running. The number of retries depends on the protocol
that is being used.
This message may be displayed during a download. The S3 file
addresses physical addresses in the operating device. The transmis-
sion is aborted as soon as invalid addresses are detected during this
process. The starting address of the invalid line in the S3 file is speci-
fied in hexadecimal format.
Is displayed during a download if the Flash Eprom cannot be pro-
grammed. This message indicates that the application memory is
defective. The starting address of the invalid line in the S3 file is speci-
fied in hexadecimal format.
Error during transmission of the application description. The error has
either occurred during the serial transmission or the S3 file contains
invalid lines or no valid S3 file has been transmitted. Recompile the
application description and attempt to retransmit.
Error during transmission of the application description. An error was
detected in the S3 file of the application description. More bytes were
received in one of the transmission lines than specified in the byte
count.
Transmission format of the application description contains errors. The
output file used has not been generated by this programming system.
The transmitted file did not contain S0, S3 or S7 lines, no S3 format
was used.
The user mode switch S4 was at the "on" position when the supply volt-
age for the operating device was switched on. The Flash data will be
retained if the following instructions are complied with. Switch the
device off, set S4 to "off" position, switch device on - data will be
retained and the device will function as before. If S4 is set to the off-
position while power is on - data will be lost, the device switches to the
download mode!
The version of the programming system and the operating system in
the operating device are not compatible. This error occurs if the wrong
operating system version was selected for compilation of the applica-
tion description. The two program versions must match.
The protocol driver loaded via the programming system and the operat-
ing device’s operating system do not match. The two program versions