Standard Mode
5.22.2.24 System Message 24 - Data set format
The size or internal version identifier of a data set loaded from the PC
to the operating device and the corresponding values in the program-
ming software do not match.
5.22.2.25 System Message 25 - Number invalid
The bit pattern read from the controller is not valid for a floating point
number. The number is output as 0,0.
5.22.2.26 System Message 26 - Loop-through active
The selected action was not performed due to an active loop-through
operation.
5.22.2.27 System Message 27 - No data set address
The addresses for the data set transfer did not exist at the time of the
controller's request.
5.22.2.28 System Message 28 - Recipe unknown
You attempted to select a recipe that does not exist in the operating
device.
5.22.2.29 System Message 29 - Data set download
You initiated a data set transfer to the controller (download), but the
Data Set Download Release bit in the Write coordination byte (bit 4)
has not yet been set by the controller.
5.22.2.30 System Message 30 - Scanner error
Three different types of errors may have occurred:
1. A value was scanned, but the editor required was not open yet.
2. The scanner does not support this variable type.
3. The parameter settings for the scanner (prefix and postfix) are not
correct.
5.22.2.31 System Message 31 - Print log unknown
You selected a print log that does not exist.