Standard Mode
characters. When you are allocating the different passwords, think of
how you want to structure access authorizations.
Example:
Password for the manufacturer of the plant, machine, and so on
Password for on-site service
Password for the person setting up the machine, foreman, overseer
Password for the operator of the system
The passwords are stored in the operating device’s Flash memory.
These passwords are the basic setting that is active when you first start
up the system after each download. The passwords are also stored in
the operating device’s RAM.
You can reactivate the passwords stored in the Flash memory by writ-
ing to the system variable FlashPasswd.
You can change all passwords from the operating device, except for
the master password (first password in the list). To do this, write the
password to be changed to the system variable MskchgPasswd.
You must then write the new password twice to the system variable
ChangePasswd. The new password is valid immediately, provided
you enter the same new password twice. If this is not the case, a corre-
sponding system message is issued and the password is reset.
Passwords are stored and compared as 11-character strings. Use the
alphanumeric editor to enter the passwords in the operating device.
Program passwords globally, and not on a language-specific basis.
See chapter “FlashPasswd“ on page 5-80.
See chapter “MskChgPasswd“ on page 5-79.
See chapter “ChangePasswd“ on page 5-80.