Technical data
R911305038 / 01 | Rexroth VCP-Operating Concept Electric Drives and Controls | Bosch Rexroth AG 5-131
Standard Mode
Example 1: You want to load the language with the number 4.
Write the hexadecimal number 7FE3 to the address of the serial mes-
sage channel.
Example 2: You want to load the language with the number 12. Write the hexadec-
imal number 7FEB to the address of the serial message channel.
5.16.5 Automatic Data Release for Scanner Module
You can use the following control code from the controller, to have the
operating device automatically read in the values from the connected
scanner.
Hexadecimal code: 7FF2h
5.16.6 Reload Event-Controlled Variable Values
You can use the following control code from the controller, to instruct
the operating device to read all variable values from the controller
again that are currently displayed in a mask and have the property
Event-Controlled.
Hexadecimal code: 7FF3h
5.16.7 Transfer Single Data Set from Operating Device to Controller
You can use the following control code from the controller, to have a
single data set transferred from the operating device to the controller.
You must write the number of the data set to the variable defined for
this purpose. In addition, you need to define the corresponding vari-
ables for the transfer buffers.
Hexadecimal code: 7FF4h
5.16.8 Delete Acknowledged Messages from Serial Message Memory
You can use the following control code from the controller, to have all
acknowledged messages of the operating device's serial message sys-
tem erased.
In addition, the delete variable must contain the value E216h. This is to
help avoid unintentional deletion. The delete variable is deleted in the
system parameters for the serial message system.
Hexadecimal code: 7FF5h