Technical data

5-130 Bosch Rexroth AG | Electric Drives and Controls Rexroth VCP-Operating Concept | R911305038 / 01
Standard Mode
5.16.1 Delete Data Logger
You can use the following control codes from the controller, to have the
operating device delete the data logger values.
Hexadecimal code: 7FC7h deletes data logger 1
7FC8h deletes data logger 2
7FC9h deletes data logger 3
7FCAh deletes data logger 4
5.16.2 Trigger Data Logger
You can use the following control codes from the controller, to have the
operating device trigger a data logger to log a new value.
Hexadecimal code: 7FCBh triggers data logger 1
7FCCh triggers data logger 2
7FCDh triggers data logger 3
7FCEh triggers data logger 4
5.16.3 Write Values of Running Time Meters to Controller
You can use the following control code from the controller, to have the
operating device pass the values of the running time meters to the con-
troller.
Only the values of active running time meters are transferred.
Hexadecimal code: 7FCFh
5.16.4 Switch to Another Language
You can use the following control code from the controller, to have the
operating device switch to another language.
The number of the language is the least significant digit of the hexcode.
Valid hexadecimal values for the language number are 7FE0h to
7FEFh.
Valid decimal values for the language number in the Language Param-
eters dialog are 1 to 16.
Hexadecimal code: 7FExh