Technical data

5-102 Bosch Rexroth AG | Electric Drives and Controls Rexroth VCP-Operating Concept | R911305038 / 01
Standard Mode
CFCardError
5.5.17.20 Set of Curves (Graph)
DataLogTrig
Function Displays errors that occurred while using the Compact Flash card.
Data type Numeric
Representation
type
Positive decimal number, alphanumeric, selection text, selection im-
age, hexadecimal number, binary number
Configurable val-
ues
0 No error
1 No Compact Flash card in device.
2 The requested file does not exist on the Compact Flash card.
3 The Compact Flash card is full or write-protected.
4 The file already exists on the Compact Flash card.
5 File has the wrong file extension.
6 S3 file is for the wrong device type.
7 S3 file is for the wrong memory type.
8 The Compact Flash card was detected.
Function Release a trigger event for a data logger.
Data type Numeric
Representation
type
Positive decimal number, alphanumeric, selection text, selection im-
age, hexadecimal number, binary number
Configurable val-
ues
0 Initial state
1 Trigger for data logger 1
2 Trigger for data logger 2
3 Trigger for data logger 3
4 Trigger for data logger 4