Technical data

R911305038 / 01 | Rexroth VCP-Operating Concept Electric Drives and Controls | Bosch Rexroth AG 5-93
Standard Mode
StartCalibrationTouch
StateCalibrationTouch
MaskStartupTime
Function Starts the calibration process for the touch-screen.
Data type Numeric
Representation
type
Positive decimal number, alphanumeric, selection text, selection im-
age, hexadecimal number, binary number
Configurable val-
ues
0 Inactive
1 Starts the calibration process
Once you have set the system variable to the value 1, the next two touch
screen touches are used for calibration! You must set up the system
variable StateCalibrationTouch to ensure that operators will know how
to proceed.
Function Displays the calibration status.
Data type Numeric
Representation
type
Positive decimal number, alphanumeric, selection text, selection im-
age, hexadecimal number, binary number
Configurable val-
ues
0 Touch to calibrate (the operator starts the calibration process with
the next touch)
1 Touch left pixel (the operator needs to touch a specific coordinate at
the top left)
2 Touch right pixel (the operator needs to touch a specific coordinate
at the lower right)
3 Calibration successful (calibration process complete)
For the user interface, we recommend that you create a text list or an
image list, and that you present the instructions to the operator as se-
lection text or a selection image.
Function Displays how much time (in milliseconds) has elapsed for mask
build-up.
Data type Numeric
Representation
type
Positive decimal number, alphanumeric, selection text, selection im-
age, hexadecimal number, binary number
Configurable val-
ues
--- Milliseconds