Technical data
R911305038 / 01 | Rexroth VCP-Operating Concept Electric Drives and Controls | Bosch Rexroth AG 5-83
Standard Mode
DSCopy
DSDelete
ActDSName
Function Copies the current data set to the destination indicated in DestDSNr.
Data type Numeric
Representation
type
Positive decimal number, alphanumeric, selection text, selection im-
age, hexadecimal number, binary number
Configurable val-
ues
0 Inactive
1 Copy to destination in DestDSNr
2 Automatically copy and search a free data set
3 Copy to destination in DestDSNr and overwrite any data set existing
Function Deletes the current data set.
Data type Numeric
Representation
type
Positive decimal number, alphanumeric, selection text, selection im-
age, hexadecimal number, binary number
Configurable val-
ues
0 Inactive
1 Deletes the active data set and activates the first data set of the rec-
ipe.
2 Deletes all data sets of the current recipe and activates the default
data set of the recipe.
Function Name of the current data set.
Data type Alphanumeric
Representation
type
Alphanumeric
Configurable val-
ues
30 characters