User guide
7
Power Xpress™ Bollard Charge Station
User Guide
EL-50600-17 Rev. A
ProductSpecications
Voltage and Wiring
(120V above ground)
• 240VAC single-phase: L1, L2, and safety ground.
• 208VAC 3-phase, wye-connected: Any 2 phases and
safety ground.
• 240VAC 3-phase, delta-connected: with center tap
on one leg, use only the two phases on either side of
the center tap. The two phases must both measure
120V AC to ground. Do not use the third leg (208V
“stinger”).
Voltage and Wiring
(230V above ground - Europe)
230V AC single-phase: LINE, NEUTRAL, and EARTH
Current and Frequency • Current –Model dependent; see unit specification label
• 50/60Hz
Cable Length and Connector Maximum: 25 ft (7.62 m) per NEC 625
Model dependent; see unit specication label (18 ft typi-
cal)
Dimensions Customer specic
Weight Bollard: Approximately 20 lb/ft
EVSE: 35 lb
Operating Temperature -40°F to +122°F (-40°C to +50°C)
Storage Temperature -58°F to +176°F (-50°C to +80°C)
Ratings and Agency Approvals Enclosure Type NEMA 4X – indoor/outdoor use, watertight
• ETL approved to UL and CSA standards
• CE compliant w/3rd-Party ETL testing
• FCC Part 15 Class-B compliant










