Specifications
BMA180
Preliminary data sheet
Bosch Sensortec
Rev. 1.0 Page 72 / - proprietary information - 06 March 2009
© Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such
as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany.
Specifications within this document are preliminary and subject to change without notice. Document is not intended for publication.
11 Package
11.1 Outline dimensions
The sensor housing is a standard LGA package. It is compliant with JEDEC Standard MO-
220C. Outline dimensions are shown below.
11.2 Orientation: polarity of the acceleration output
If the sensor is accelerated into the indicated directions, the corresponding channels will deliver
a positive acceleration signal (dynamic acceleration).
Example: If the sensor is at rest or at uniform motion in a gravity field according to the figure
given below, the output signals are:
• ± 0g for the X channel
• ± 0g for the Y channel
• + 1g for the Z channel
+z
+x
top side
+y
gravity vector