User manual
NurseCall Main Unit Programming | en 53
TeleAlarm SA® User Manual 953.92 | v1.0 | 2007.07
7.4.7 Standard NurseCall selection
This command allows to set the NurseCall as standard. This is the default value.
1. Type the code 001998.
2. Confirmation message displayed.
7.4.8 Universal NurseCall selection
This command allows to set the NurseCall as ''Universal NurseCall''. If this mode is selected,
the following parameters are automatically set:
– Display Mode set as FL,RO,BE (Floor/Room/Bed);
X See Section 7.2.4 Display Mode, page 38.
– RS-232 output set as Alarm Management SW;
X See Section 7.3.6 RS-232 output setting, page 46.
–50 Events selected.
X See Section 7.4.11 Maximum number of Events buffered (toggle), page 55.
The ''Universal NurseCall'' breaks the limitation of 300 or 500 Transmitters by using a concept
in which the Transmitters are not recorded inside the NurseCall Main Unit.
In fact, the NurseCall Main Unit directly transfers each incoming radio ID code received from
the radio or from a Relay Unit to its RS-232 communication port.
The Alarm Management Software handles the radio codes.
The ID code is sent according to Display Mode Floor / Room / Bed.
Example:
ID code 1234 => Floor = 1; Room = 23; Bed = 4
!
CAUTION! It is necessary to perform a general RESET before changing this value.
X See Section 7.4.2 Resetting all parameters (including date and time), page 51.
UNIVERSAL NC? NO !
............
!
CAUTION! It is necessary to perform a general RESET before changing this value.
X See Section 7.4.2 Resetting all parameters (including date and time), page 51.