@ INSTALLATION BOSCH INSTRUCTION MANUAL for Bosch Electric Built-in Ceramic Cook-top Models NKT 72 and NKT 92 MANUEL D'INSTALLATION Surface de cuisson _lectrique en €_r.amique encastr_e ModUles NKT 72 et NKT 92 BEFORE YOU BEGIN, READ THESE INSTRUCTIONS PLETELY AND CAREFULLY. VEUILLEZ LIRE ATTENTIVEMENT COMMENCER L'INSTALLATION. CE MANUEL AVANT DE r IMPORTANT: Save these instructions for the local electrical inspector's use INSTALLER: Please leave this manual with owner for future reference.
Introduction Table of Contents 3 Tools You Will Need power 'Requirements Counter Preparation Steps for Installation Technical Data Preparing the Location for 30" Cook-Top 5 for 36" Cook-Top 6 Attaching Fastening 7 Rails Placing the Cook-Top 8 Electrical Electrical 9 Supply Connections 10 Final Check List 11 Schematic 12 Wiring Diagrams 14 Introduction Table des mati_res Les outils dont vous aurez besoin Sp6cifications Preparation _lectriques requises du comptoir I_tapes de l'i
Introduction Please read these instructions COMPLETELY AND CAREFULLY. They will save you time and effort and help to ensure optimum cook-top performance. Be sure to observe all WARNINGS. These installation instructions are intended for use Counter space must be provided for installation of your new cook-top. When choosing a location consider the following IMPORTANT CONSIDERATIONS: • Cabinet storage space located above the cook-top should be avoided, to eliminate the by a qualified installer.
Technical Data NKT 72 series, (30", 4 element) Dimensions, NK'F 72 a Height 4" 102 mm b Width 30" 762 mm c Depth 20U2" 521 mm a Electrical Rating, NKT 72 Volts Hertz Amperes Watts 240 60 40 7 900 208 60 28 6 000 NKT 92 series, (36", 5 element) Dimensions, NKT 92 a Height 4" 102 mm b Width 36" 914 mm c Depth 201/_'' ..
Preparing the Location for 30", four Element Cook-Top 30"(762mm) rain cabinet width above cooktop For minimum cJearences see note* depth Lower cabinet depth: Openin >25 (635 ram) for combinationwith _/ downdraft fan ...._/2-1/2 >24 (610 ram) without downdraft fan (63.5mm) 2-1/4"(57mm) counter space both sides of cutout from a combustible surface Work top: box heightJ . • Note: rain Locate supply junction box on wall 12"(305mm) or more above the floor line 24" rain.
Preparing the Location for 36", five Element Cook-Top 36"(914mm) min above ccoktop cabinet width 13"(330mm)max upper cabinet depth 35-1/4"(895mm) width Lower cabinet depth: >25"(635 mm) for combination with downdraft fan. >24"(610 mm) without downdraft fan Burner box height min 2-1/4"(57mm) counter space both sides of cutout from a combustible surface Work Locate supply junction box on wall 12"(305mm) or more above the floor line • Note: top:. For minimum clearenoes see note" 24" min.
Attaching Fastening Rails used for both NKT 72 and NKT 92 series 90* To attach the fastening rails: I. Mark the center as shown in drawing. 2. Align rails using notch. 3. Secure the rails tightly using screws. Note: a. The top flange of rail must sit tightly against the counter top. b. If counter top is tiled, the lower screws holes in the rails should be used. Important: • Do all counter top preparation, before installing the cook-top.
Placing the Cook-Top 1. Thread the cable through the cutout opening. 2. Gently place the cook-top into the cutout, taking care to assure that cable does not become pinched between the cook-top and the counter cutout, and press in place so that cook-top interlocks with rails. Note: If installing on a tiled counter top, seal the tile joints with silicone rubber. NKT 92 series shown SPECIAL NOTE: Do not install the cooktop over a refrigerator, dishwasher or washing roac!!he.
Electrical Supply Before installing the cook-top have a qualified WIRING electrician verify that your home is provided with When making the wire connections, use the entire adequate electrical service and that the addition of length of the conduit provided (3 feet)• The conduit must not be cut. the cook-top will not overload the branch circuit REQUIREMENTS on which it is to be installed.
J t -i Electrical Connections Cable from power supply This appliance is manufactured with a green and yellow striped GROUND wire connected to the cook-top chassis. After making sure that the power has been turned off connect the flexible conduit from the cook-top to the junction box using a U.L. Grounded neutral Junction box Red wires listed conduit connector, see figures A and B.
Final Check List To prevent improper connection leading to damage of electrical components and so voiding the warranty, the following steps must be performed: 1. Check the electrical requirements and make sure you have the correct electrical supply and that the cook-top is properly grounded. 2. Make sure all control knobs are in the off position. 3. Turn on the power supply to the cook-top. 4. Check power at jnnction box wires using a volt meter having a range of 0-250 VAC.
Schematic Wiring Diagrams (7 NKT 72 series _rM i r"- i * -- ---:-] NKT 92 series t4_ t_ i B te I I _431 N2_ _ i__iii I -,l!' _,_ .