Operation Manual
Table Of Contents
- IVA 4.0
- Table of Contents
- 1 Introduction
- 2 Requirements
- 3 Configuration
- 4 IVA 4.0
- 5 IVA 4.0 Flow
- 6 IVA and VG4 AutoDome
- 7 Display of Units of Measurement
- Index
50 en | IVA 4.0 Flow IVA 4.0
DOC | 4.0 | 2009.06 Operating Manual Bosch Security Systems
1Tasks
When this tab is selected, you can see all the defined tasks. You have the option to
create new tasks and to edit or delete existing ones.
(See: Section 5.3 Tasks, page 52)
2 Statistics
When this tab is selected, the statistics for the detected flows are displayed.
(See: Section 5.5 Statistics, page 56)
3 Configuration
When this tab is selected, you can access all of the necessary basic settings:
– Sensitivity Settings
(see: Section 5.6.1 Sensitivity Settings, page 57)
4 Depending on the tab selected, the following are displayed here:
– an overview of the defined tasks
– statistics on a selected field
– sensitivity configuration settings
5 Camera image
The camera image is displayed irrespective of the tab selected.
If the Tasks tab is selected, the popup menu in the camera window, for example,
enables fields to be created and changed.
(See: Section 5.2.1 Popup Menu in the Camera Image, page 51)
6 In this area, all the buttons are displayed that are required for work in the selected tab.
7OK
This saves the settings for IVA 4.0 Flow and closes the window.
Incomplete settings are not saved.
8Cancel
The IVA Wizard is closed.
Any changes that were made after the IVA Wizard was launched and not saved to the
device will be lost.