Technical data
18
Operation
6 720 617 760 (2008/09)
5.3 Changing the standard setting of the required
room temperature
B Accessing user level: Hold down mode for approx. 3 seconds
until – – is displayed.
B Release the mode key and turn until the required param-
eter is shown:
– 1A p = Required room temperature for Comfort
– 1b p = Required room temperature for Economy
– 1C p = Required room temperature for Frost
B Briefly press : The current temperature for the previously
selected parameter will be displayed.
B Briefly press : The current temperature flashes.
B Turn to adjust the required room temperature:
– Comfort = maximum required temperature (e.g. when
the living space is occupied and occupants require a com-
fortable room temperature). Setting range higher than
Economy up to 30 °C.
–
Economy
= average required temperature (e.g. if a low
room temperature is adequate or if everyone is away or
asleep and the house should not cool down excessively). Set-
ting range higher than
Frost
and lower than
Comfort
.
– Frost = minimum required temperature (e.g. if everyone
is away or asleep and the house should not cool down
excessively). Consider any pets and plants. Setting range
lower than Economy down to 5 °C.
Use this function if you want to permanently change
the required room temperature away from the
standard setting.