INSTALLATION & USER INSTRUCTIONS INTELLIGENT ROOM THERMOSTAT FR 10 6 720 617 760 (2008/09) 6 720 613 547-00.
Dear customer, Dear customer, Congratulations on having decided in favour of a top-quality product from our company. The FR 10 offers everything you can expect from a modern heating control: It is both reliable and energy saving. Like all Bosch Group products, the FR 10 has been produced and tested according to the most stringent quality standards so that you can enjoy the Worcester warmth for a long time to come.
Contents Contents 1 Symbols and safety precautions . . . . . . . . . . . . . . . . . . . . 4 1.1 Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 1.2 Safety precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 2 Technical data for the accessory item . . . . . . . . . . . . . . . . 2.1 Standard package . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.2 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.
Symbols and safety precautions 1 Symbols and safety precautions 1.1 Symbols Safety instructions in this document are identified by a warning triangle and are printed on a grey background. Signal words indicate the seriousness of the hazard in terms of the consequences of not following the safety instructions. • Caution indicates that minor damage to property could result. • Warning indicates that minor personal injury or serious material losses could result.
Symbols and safety precautions 1.2 Safety precautions B These instructions must be observed to ensure correct operation. B Install and commission the boiler and all accessories in accordance with the associated instructions. B Allow only qualified installers to install accessories. B Only use these accessories in conjunction with the heating appliances listed. Follow the connection diagram! B Do not connect this accessory to the 230 V mains electricity supply.
Technical data for the accessory item 2 Technical data for the accessory item The FR 10 can only be connected to a boiler with BUS-enabled Heatronic 3. • The FR 10 enables the room temperature control of a single heating system. • The FR 10 must only be used in conjunction with a suitable time switch, MT 10 or DT 20. • In systems with a single heating system, you can change automatically between the currently set operating mode / / or heating operation off using the time program of a time switch.
Technical data for the accessory item Standard package 6 720 613 547-03.1R 2.1 1 2 Fig. 1 1 2 2.2 Top section, controller and base for wall mounting Installation and operating instructions Technical data Dimensions 85 mm × 100 mm × 35 mm H×W×D Rated voltage 10 ... 24 V DC Rated current ≤ 3.5 mA Controller output 2-wire BUS Control range 5 ... 30 °C in steps of 0.5 K permiss. ambient temp. 0 ... +50 °C Class of protection III Protection level IP20 Tab.
Technical data for the accessory item 2.3 Supplementary accessories • MT 10: Mechanical single channel time switch. • DT 20: Twin channel digital programmer. 2.4 Cleaning B If required, use a damp cloth to wipe the controller casing. Never use aggressive or acidic cleaning agents for this.
Installation (for installers only) 3 Installation (for installers only) DANGER: Risk of electric shock B Before installing these accessories: Isolate the voltage supply (230 V AC) to the heating appliance and all additional devices on the bus. 3.1 Installation The installation location must be suitable for controlling the heating system or heating circuit. The accuracy of the FR 10 is dependent upon the installation location.
Installation (for installers only) B Select the installation location. 25 mm 100 mm 0,6 m 1,0 m 85 mm 0,75 m 1,2 m 35 mm 6 720 612 218-02.1J Fig.
Installation (for installers only) B Remove the top section from the base. 3. 1. 2. 6 720 612 218-04.1R Fig. 3 The mounting surface on the wall should be level.
Installation (for installers only) B Fit the base. 6 mm 3,5 mm 6 mm 3,5 mm 6 720 612 218-05.1R Fig. 4 B Connect to the power supply. Heatronic 3 FR 10 B B ST 19 A F 1 2 4 B B 6 720 613 554-01.1R Fig. 5 B Push on top section.
Installation (for installers only) 3.2 Disposal B Dispose of packaging in an environmentally responsible manner. B When replacing components, dispose of the old parts in an environmentally responsible manner. 3.3 Electrical connections B BUS connection from the controller to other BUS subscribers: Use electrical cable with the minimum specification H05 VV-... (NYM-I...). Permissible cable lengths from the BUS-enabled Heatronic 3 to the controller: Cable length Cross-section 80 m 0.
Commissioning (for installers only) 4 Commissioning (for installers only) 1 Switch on the system. 2 During first commissioning or after a global reset (resetting all adjustments): B Confirm the flashing code 1 HC by pressing . 3 System configuration starts automatically, and lasts approximately. 60 seconds during which time AC will be displayed.
Operation Operation 6 720 613 554-02.1R 5 mode 1 2 Fig.
Operation Controls 1 Rotary selector : - Turn = Adjust value - Press = Confirm setting/value 2 Mode key: - Change operating mode - Accessing user level = hold down for approx. 3 seconds - Accessing installer level = Hold down for approx.
Operation 5.1 Changing the operating mode B Briefly press mode until the required operating mode is displayed. = constant Comfort = constant Economy = constant Frost The selected operating mode is only enabled if the heating operation is not blocked. 5.2 Changing the required room temperature Use this function if you want to change the required room temperature by way of an exception, e.g. for the duration of a party.
Operation 5.3 Changing the standard setting of the required room temperature Use this function if you want to permanently change the required room temperature away from the standard setting. B Accessing user level: Hold down mode for approx. 3 seconds until – – is displayed.
Operation B Briefly press to save the value. B Press mode until the current room temperature is displayed. 5.4 Adjusting the installer level (for installers only) The installer level is exclusively designed for installers. B Accessing installer level: Hold down mode for approx. 6 seconds until – – – is displayed.
Operation 5.4.1 Changing the code (parameter: 5A p) Setting range: 1 to 10 Use this parameter if you want to adjust the code after commissioning: B For systems with a single heating circuit: Select code 1. Only one FR 10 can be used per heating system. 5.4.
Operation 5.4.3 Adjusting the room temperature sensor (parameter: 6A p) Setting range: – 3.0 °C (K) to +3.0 °C (K) Use this parameter if you want to correct the displayed room temperature. B Position a precision instrument near FR 10. The precision instrument must not transfer any heat to the FR 10. B Keep other heat sources, such as sunlight, body heat etc. away for one hour. B Adjust the displayed room temperature correction value. 5.4.
Operation 5.4.5 Selecting amplification factor V (parameter: 6C p) Setting range: 40 % to 100 % Subject to changes in room temperature, the amplification factor V influences the heat demand. B Selecting amplification factor V: – ≤ 50 %: Select a lower factor to reduce the influence on the heat demand. The selected room temperature is achieved after a longer time with only little overshoot. – ≥ 50 %: Select a higher factor to increase the influence on the heat demand.
Operation 5.5 Selecting the heating program B Select the heating program with start and stop switching times at the time switch (Æ time switch operating instructions). 5.6 Frost protection The heating (circuit pump) starts if the room temperature in the room where the FR 10 is installed falls below 4 °C or the flow temperature falls below 8 °C. The heating system is started and stopped accordingly to maintain the room temperature of 4 °C or the flow temperature of 8 °C.
Troubleshooting 6 Troubleshooting If the boiler has developed a fault, the display will show, for example, EA. E. Here, EA means a boiler fault; the full stop . means an external fault; E means error (= fault). If the FR 10 has developed a fault, the display will show, for example, 03 E. Here, 03 refers the the fault number at the FR 10 and E stands for error (= fault): B Contact your installer. If several faults are active, the fault with the highest priority is displayed.
Troubleshooting Fault Cause Remedy Required room temperature not achieved. Thermostatic valve(s) are not opened sufficiently. Fully open the thermostatic valve(s) or ask your installer to check the valves. Central heating temperature Set the central heating control on the boiler set too temperature controll low. higher. Air in the heating system. Bleed radiators and vent the heating system. Required room FR 10 installed in an unfatemperature vourable location, e.g. extergreatly exceeded.
Troubleshooting If the fault persists: B Call your installer or customer service and inform them of the fault, quoting the appliance details (from the type plate). Appliance details Type: ........................................................................................................ Part number: ........................................................................................................ Date of manufacture (FD...): ........................................................................
Tips on saving energy 7 Tips on saving energy • Regulate the temperature in adjacent rooms via thermostatic valves. • External heat in the room where th FR 10 is installed (e.g. solar gain, stove etc.) can result in too little heating in adjacent rooms (the heating system remains cold). • Much energy can be saved by reducing the room temperature via economy phases. Reducing the room temperature by 1 K ( °C) enables up to 5% energy to be saved.
Environmental protection 8 Environmental protection Environmental protection is a fundamental corporate strategy of the Bosch Group. The quality of our products, their economy and environmental safety are all of equal importance to us and all environmental protection legislation and regulations are strictly observed. We use the best possible technology and materials for protecting the environment taking account of economic considerations.
Notes 6 720 617 760 (2008/09) 29
Notes 30 6 720 617 760 (2008/09)
Notes 6 720 617 760 (2008/09) 31
067206177608 CONTACT INFORMATION WORCESTER, BOSCH GROUP: TECHNICAL: 08705 266241 SERVICE: 08457 256206 SPARES: 01905 752571 LITERATURE: 01905 752556 TRAINING: 01905 752526 SALES: 01905 752640 WEBSITE: www.worcester-bosch.co.uk Dedicated to heating comfort Worcester, Bosch Group Cotswold Way, Warndon, Worcester WR4 9SW Tel. 01905 754624 Fax. 01905 754619 Worcester, Bosch Group is a brand name of Bosch Thermotechnology Ltd. www.worcester-bosch.co.