Technical data

Notes
1. Bosch OSRD camera Address change: The camera address may be changed using the
following sequence of commands. This is similar to the “Fast Address” for AUTODOME VG4
model cameras, but utilizes a different set of AUX numbers and there are not any OSD
messages displayed during this process.
AUX ON 14 (Initiate Fast Address sequence)
AUX ON 21 (Confirms that fast Address is desired)
AUX OFF 21 (Camera is set to receive the new address)
AUX OFF #; where # is the new address number for the camera
2. AutoPan is not enabled for the MIC440 with Bosch protocol.
3. Inverted Image is not enabled for the MIC440 with Bosch protocol.
Additional Pelco Functions for MIC440
Aux #/Functions
Go To Preset #
Set Auto Home Time to 10 secs 40
Set Auto Home Time to 30 secs 41
Set Auto Home Time to 1 min 42
Set Auto Home Time to 5 mins 43
Set Auto Home Time to 10 mins 44
Aux 1 On : Auto Focus On* 50
Aux 2 On : Digital Zoom On* 51
Aux 3 On : Auto Exposure On* 52
Aux 4 On : IR On* (B/W Night mode) 53
Aux 5 On : Wiper On* 54
Aux 6 On : Washer ONLY On* 55
Aux 7 On : OSD On* 56
Aux 8 On : Backlight On* 57
Aux 1 Off : Auto Focus Off* 58
Aux 2 Off : Digital Zoom Off* 59
Aux 3 Off : Auto Exposure Off* 60
Aux 4 Off : IR Off* (Color Day mode) 61
Aux 5 Off : Wiper Off* 62
Aux 6 Off : Washer Off* 63
Aux 7 Off : OSD Off* 64
Aux 8 Off : Backlight Off* 65
Note that Pelco auxiliaries can be re-mapped; therefore, the preset value may change as
modified. The values in this table above represent the factory default configuration for Pelco
protocol.
MIC440 Explosion-protected Camera Operation | en 47
Bosch Security Systems, Inc. Operation Manual 2013.11 | 8.1 |