LTC 8561, 8564/20, 8566 Series Instruction Manual EN Single Channel On-site Receiver/Drivers
8561 | Instruction Manual | Important Safeguards EN | 2 Important Safeguards 1. Read, Follow, and Retain Instructions - All safety and operating instructions should be read and followed before operating the unit. Retain instructions for future reference. 2. Heed Warnings - Adhere to all warnings on the unit and in the operating instructions. 3. Attachments - Attachments not recommended by the product manufacturer should not be used, as they may cause hazards. 4.
EN | 3 8561 | Instruction Manual | Safety Precautions For Indoor Product 1. Water and Moisture - Do not use this unit near water - for example, in a wet basement, in an unprotected outdoor installation or in any area classified as a wet location. 2. Object and Liquid Entry - Never push objects of any kind into this unit through openings, as they may touch dangerous voltage points or short out parts that could result in a fire or electrical shock. Never spill liquid of any kind on the unit. 3.
EN | 4 8561 | Instruction Manual | FCC & ICES Information FCC & ICES INFORMATION Sicherheitshinweise (U.S.A. and Canadian Models Only) This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.
EN | 5 8561 | Instruction Manual | Safety Precautions Veiligheidsmaatregelen VOORZICHTIG: OPEN DE BEHUIZING OF DE ACHTERKANT VAN HET APPARAAT NIET. ZO VERMINDERT U HET RISICO OP ELEKTRISCHE SCHOKKEN. IN HET APPARAAT BEVINDEN ZICH GEEN ONDERDELEN DIE U ZELF KUNT REPAREREN. LAAT SERVICE EN ONDERHOUD UITVOEREN DOOR GEKWALIFICEERD PERSONEEL. Medidas de Segurança CUIDADO: PARA REDUZIR O RISCO DE CHOQUE ELÉCTRICO, NÃO RETIRE A TAMPA (OU A PARTE POSTERIOR).
8561 | Instruction Manual | Table of Contents EN | 6 Table of Contents Important Safeguards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 FCC Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 1 UNPACKING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
EN | 7 8561 | Instruction Manual | Unpacking 1 UNPACKING Unpack carefully. This is electronic equipment and should be handled carefully. Check for the following items: • LTC 8561 Series, LTC 8564/20, or LTC 8566 Series Receiver/Driver. If any items appear to have been damaged during shipping, contact the shipper. If any items are missing, notify your Bosch Security Systems, Inc. Sales Representative or Customer Service Representative.
EN | 8 8561 | Instruction Manual | Installation 4 INSTALLATION CAUTION: This installation should be performed by qualified service personnel only in accordance with the National Electrical Code, Canada Electrical Code, or applicable local codes. All units are 50/60 Hz line frequency compatible. All units have low voltage DC lens drivers (6 volts or 12 volts selectable) for focus, zoom, and iris with adjustable speed. There are also four auxiliary outputs.
EN | 9 8561 | Instruction Manual | Installation DIP Switch Function On Off S101 #1 #2 #3 #4 Auxiliary Auxiliary Auxiliary Auxiliary Latch Latch Latch Latch Momentary Momentary Momentary Momentary Reverse Aux 7/ Aux 1 Software Control Normal Aux 1/ Aux 7 Hardware Control S102 #1 #2 #3 (Reserved) Lens Polarity Auto-/Randompan Auto-pan Type #4 S103 #1 #2 #3 #4 S104 #1 #2 #3 #4 4.4 1 2 3 4 Pre-position Adj.
EN | 10 8561 | Instruction Manual | Installation assigned to Auxiliary #1 and random-pan is assigned to Auxiliary #7. With the switch in the ON position, auto-pan is assigned to Auxiliary #7 and random-pan is assigned to Auxiliary #1. This allows the LTC 5135 Series Controller/Followers to access the random-pan function through its Auxiliary #1. The random-pan function works only when the autopan software control mode of operation is selected. This is selected by using switch #4 of S102, Auto-pan. 4.
EN | 11 8561 | Instruction Manual | Installation 4.16 Field Setup To reduce the chance of external interference, minimize the cost of wire, and avoid excessive voltage losses in the multiconductor cables, the receiver/driver should be located as close to the pan/tilt as possible. This also allows for convenient use of the local test feature. The receiver/driver should also be mounted in a secure place out of direct sunlight.
EN | 12 8561 | Instruction Manual | Installation If the signal is to end here, confirm that the supplied termination resistor is installed as prescribed below. Locate connector J121, BIPHASE, and proceed with the following steps. 1. Prepare the end of the signal cable, properly identifying the plus and minus phases. 1. One end of the supplied 100 ohm resistor (or equivalent resistance) to terminal 4 of the signalin terminal block. 2.
EN | 13 8561 | Instruction Manual | Installation 4.21 Connecting Lens Motor Locate connector J105, LENS DRIVE for the lens, and follow the steps below to wire the motorized lens. 1. Prepare the ends of the cables by stripping about 1⁄4-inch of insulation from the ends. 2. Connect the lens ground cable to conductor 4 on terminal strip, J105. 3. Connect the lens zoom cable to conductor 1 on terminal strip, J105. 4. Connect the lens focus cable to conductor 2 on terminal strip, J105. 5.
EN | 14 8561 | Instruction Manual | Installation 1. Prepare the ends of cables by stripping about 1⁄4-inch of insulation from the ends. Refer to the two following sections for connection details. 2. Connect the pan-right wire to conductor 1 on terminal strip, J406. 4.25 Auxiliary Supply Output 3. Connect the pan-left wire to conductor 2 on terminal strip, J406.
EN | 15 8561 | Instruction Manual | Local Test Operation 4.27 Power Up Operation CAUTION: The receiver/driver performs a calibration test which operates the pan/tilt and zoom lens motors when AC power is first applied to the unit. Ensure that movement of the pan/tilt during this power-on test will not cause damage or create a hazardous condition before applying AC power to the unit.
EN | 16 8561 | Instruction Manual | Summary of PIN Assignments 6.2 Home Position The home position feature calls up pre-position number 1 after there has been no PTZ commands received by the receiver/driver for approximately two minutes. This feature is enabled by turning AUX-9 ON or disabled by turning AUX-9 OFF. 6.3 SUMMARY OF PIN ASSIGNMENTS 7.1 Biphase Signal Five conductor terminal block, J121, is found on right side of the top, main printed circuit board.
EN | 17 8561 | Instruction Manual | Summary of PIN Assignments 7.3.1 J105 - Lens Output Pin No. 1 Signal Name Zoom Remarks Connect to lens zoom motor wire. 2 Focus Connect to lens focus motor wire. 3 Iris Connect to lens iris motor wire. 4 Common Connect to lens motor common wire. 7.4 Pre-position Pre-positions: 82 with 5 functions each (when using continuous pan motor) or 99 with 4 functions each.
EN | 18 8561 | Instruction Manual | Illustrations 8 ILLUSTRATIONS 273.1 10.75 4ø 8.1 0.32 152.4 6.
Bosch Security Systems | 30 January 2004
Bosch Security Systems, Inc. 850 Greenfield Road Lancaster, PA 17601 USA Tel: 800-326-3270 Fax: 1-717-735-6560 www.boschsecuritysystems.com Bosch Security Systems B.V. P.O. Box 80002 5600 JB Eindhoven The Netherlands Tele +31 40 27 80000 © 2004 Bosch Security Systems GmbH 3935 890 06014 04-05 | Updated January 30, 2003 | Data subject to change without notice. Bosch Security Systems Pte Ltd.