Specifications
Digital Video Quad Processor Unpacking | en 23
Bosch Security Systems, Inc. User’s Guide F.01U.090.110 | 3.0 | 2010.04
Setting the Alarm Dwell
The ALARM DWELL sets the automatic reset period after an alarm is generated. The options
are:
– 1-99 SEC: automatic reset period.
– HOLD: alarm continues until the relevant camera key or the ALM key is pressed.
– FOLLOW: alarm continues until the external alarm signal is reset or until the relevant
camera key or the ALM key is pressed.
To set the ALARM DWELL:
1. Press the Up and Down arrow keys and select ALARM DWELL; then press the Return key.
The unit displays the following menu:
2. Press the Up and Down arrow keys to scroll through the dwell options:
–1-99 SEC
–HOLD
– FOLLOW
3. Press the Return key to exit the menu.
Setting Alarm Polarity
The ALARM POLARITY function defines how the alarm is generated for each alarm input,
either from Normally Open (NO) or Normally Closed (NC) contacts.
1. Press the Up and Down arrow keys and select ALARM POLARITY; then press the Return
key. The unit displays the following menu:
2. Press the Up and Down arrow keys to move the cursor to the required alarm input.
3. Press the Return key to toggle between NO and NC.
4. Press Up and Down arrow keys to select RETURN; then press the Return key to exit.
NOTE: Alarm functions are disabled when in Menu or Playback mode
ALARM DWELL
60 SEC
TO EXIT PRESS RETURN KEY
ALARM POLARITY
(1) INPUT 1: NO
(2) INPUT 2: NC
(3) INPUT 3: NO
(4) INPUT 4: NC
> (5) RETURN