Installation Manual

Setup
Turn the Bypass switch on to activate the bypass feature.
1
3
2
Figure 6.1: Receiver Bypass switch
Callout Description
1 Receiver
2 Bypass switch (switch 1)
3 Sensitivity control
Interruption time
Turn the sensitivity control on the receiver clockwise to reduce sensitivity and
counterclockwise to increase sensitivity.
1
2 3
4
5
Figure 6.2: Interruption time settings
Callout Description
Callout Description
1 40 ms running 4 300 ms slow walking
2 75 ms jogging 5 400 – 500 ms slow walking
3 150 – 200 ms walking
Beam power control
Turn the Beam Power Control on the transmitter clockwise to increase beam power. Turn
counter-clockwise to decrease beam power. Refer to table below. For UL applications, the
interruption time cannot exceed 75 ms.
6
18 en | Setup Photobeam 5000
2016.02 | 03 | F.01U.305.910 Installation and Operation Guide Bosch Security Systems, Inc.