Installation Manual

Setup
Turn the Bypass switch on to activate the bypass feature.
3
2
1
Figure 6.1: Receiver Bypass switch
Callout Description
1 Receiver
2 Switches (AND/OR GATE switch 4, BYPASS switch 5, and LEVEL CHECK switch 6)
3 Beam interruption time sensitivity volume
AND/OR Gate (on the receiver)
Set the dip switch 4 on the receiver to:
ON: OR GATE
OFF: AND GATE (original position)
BYPASS (on the receiver)
Set the dip switch 5 on the receiver to:
ON: BYPASS activated
OFF: BYPASS not activated (original position)
LEVEL CHECK (on the receiver)
Set the dip switch 6 on the receiver to:
ON: Perform optical alignment of the upper beam
OFF: Perform optical alignment of the lower beam (default position)
Interruption time
Turn the sensitivity control on the receiver clockwise to reduce sensitivity and
counterclockwise to increase sensitivity.
6
Photobeam 5000 Setup | en 21
Bosch Security Systems, Inc. Installation and Operation Guide 2015.01 | 02 | F.01U.303.478