Wiring
Refer to Terminal strip below for transmitter/receiver terminal locations. Use duct
pipes for outdoor wiring. Do not use aerial wiring.
!
Caution!
Complete all electrical connections and inspect them prior to applying power.
Notice!
Tamper and EDC terminals should be connected to a 24-hour supervisory loop
Notice!
Power is to be provided by a UL Listed burglar alarm power supply or burglar alarm control
panel. In case of power failure, the power supply or control unit shall have a minimum of 4
hours of standby power.
Notice!
All wiring is to be in accordance with the National Electric Code, ANSI/NFPA 70.
Notice!
This system should be tested at least once a week to ensure proper function.
Terminal strip overview
1
2
3
4
3
56
4
Figure 4.1: Terminal strip component overview
Callout ﹘ Description
Callout ﹘ Description
1 ー Receiver 4 ー Tamper
2 ー Transmitter 5 ー Alarm output
3 ー Power (non-polarized) 6 ー EDC output