IntuiKey Keyboard Keyboard Version 1.
IntuiKey Keyboard Table of Contents | en iii Table of Contents 1 Safety 1 1.1 Important Safety Instructions 1 1.2 Safety Precautions 3 1.3 Important Notices 3 1.4 Customer Support and Service 8 2 Introduction to the IntuiKey Keyboard Series 9 2.1 Unpacking 9 2.2 Understanding the IntuiKey 9 3 Installing the IntuiKey Keyboard 11 3.1 Mounting the IntuiKey 12 3.2 Connecting to the IntuiKey 13 3.3 KBD-Universal (RS-232 Protocol) Installation 15 3.3.
iv en | Table of Contents F.01U.115.018 | 1.92 | 2008.12 IntuiKey Keyboard Installation Manual Bosch Security Systems, Inc.
IntuiKey Keyboard Safety | en 1 Safety 1.1 Important Safety Instructions 1 Read, follow, and retain for future reference all of the following safety instructions. Heed all warnings on the unit and in the operating instructions before operating the unit. 1. Cleaning - Unplug the unit from the outlet before cleaning. Follow any instructions provided with the unit. Generally, using a dry cloth for cleaning is sufficient, but a moist fluff-free cloth or leather shammy may also be used.
2 en | Safety IntuiKey Keyboard 11. Power sources - Operate the unit only from the type of power source indicated on the label. Before proceeding, be sure to disconnect the power from the cable to be installed into the unit. – For battery powered units, refer to the operating instructions. – For external power supplied units, use only the recommended or approved power – For limited power source units, this power source must comply with EN60950.
IntuiKey Keyboard 1.2 Safety | en 3 Safety Precautions DANGER! Indicates a potentially hazardous situation. If not avoided, this could result in serious bodily injury or death. WARNING! High risk: ! ! This symbol indicates an imminently hazardous situation such as “Dangerous Voltage” inside the product. If not avoided, this will result in an electrical shock, serious bodily injury, or death. CAUTION! Medium risk: Indicates a potentially hazardous situation.
4 en | Safety IntuiKey Keyboard – Disconnect the unit's input connectors from outdoor equipment before disconnecting the grounding plug or grounding terminal. – Follow proper safety precautions such as grounding for any outdoor device connected to this unit. U.S.A. models only - Section 810 of the National Electrical Code, ANSI/NFPA No.
IntuiKey Keyboard Safety | en 5 Power lines - Do not locate the camera near overhead power lines, power circuits, or electrical lights, nor where it may contact such power lines, circuits, or lights. SELV All the input/output ports are Safety Extra Low Voltage (SELV) circuits. SELV circuits should only be connected to other SELV circuits. Because the ISDN circuits are treated like telephone-network voltage, avoid connecting the SELV circuit to the Telephone Network Voltage (TNV) circuits.
6 en | Safety IntuiKey Keyboard INFORMATIONS FCC ET ICES (commercial applications) (modèles utilisés aux États-Unis et au Canada uniquement) Ce produit est conforme aux normes FCC partie 15. la mise en service est soumises aux deux conditions suivantes: – – cet appareil ne peut pas provoquer d'interférence nuisible et cet appareil doit pouvoir tolérer toutes les interférences auxquelles il est soumit, y compris les interférences qui pourraient influer sur son bon fonctionnement.
IntuiKey Keyboard Safety | en 7 Disclaimer Underwriter Laboratories Inc. (“UL”) has not tested the performance or reliability of the security or signaling aspects of this product. UL has only tested fire, shock and/or casualty hazards as outlined in UL's Standard(s) for Safety for Closed Circuit Television Equipment, UL 2044. UL Certification does not cover the performance or reliability of the security or signaling aspects of this product.
8 1.4 en | Safety IntuiKey Keyboard Customer Support and Service If this unit needs service, contact the nearest Bosch Security Systems Service Center for authorization to return and shipping instructions. Service Centers USA Telephone: 800-366-2283 or 585-340-4162 Fax: 800-366-1329 Email: cctv.repair@us.bosch.com Customer Service Telephone: 888-289-0096 Fax: 585-223-9180 Email: security.sales@us.bosch.
IntuiKey Keyboard 2 Introduction to the IntuiKey Keyboard Series | en 9 Introduction to the IntuiKey Keyboard Series This manual contains all the information necessary to safely install the IntuiKey Keyboard. Consult the Table of Contents for a detailed list of topics covered. Step-by-step procedures, and illustrations guide you through each phase of IntuiKey setup. Installation of the IntuiKey includes mounting and connecting the unit to other system components.
10 en | Introduction to the IntuiKey Keyboard Series IntuiKey Keyboard The following chart provides basic operating specifications: Electrical (operating) Mechanical (construction) Voltage: Finish: Charcoal 12–15 VDC (supplied by any one or a combination of Allegiant Switcher, Divar Series digital video recorder, System4 Multiplexer, and an optional listed Class 2 or equivalent power supply Power: 5 Watts nominal Width: 12.00 in. (327.
IntuiKey Keyboard 3 Installing the IntuiKey Keyboard | en 11 Installing the IntuiKey Keyboard The IntuiKey is compatible with many controller devices. In certain configurations a single keyboard is connected to a single controller device. In other configurations a keyboard can control up to thirty (30) multiplexers/Divar Series (1, 2, XF) DVRs, and one (1) video switcher simultaneously. See the table below for supported Divar features.
12 en | Installing the IntuiKey Keyboard IntuiKey Keyboard KBD-Universal Divar Digital Video Recorder #1 PHILIPS Prod Mon Shot Clr 1 2 3 4 5 6 7 8 9 0 RS-485 Divar Digital Video Recorder #2 Divar Digital Video Recorder # 30 Allegiant Series Video Switcher RS-485 One IntuiKey to Multiple Divars (Series 1 &2) KBD-Digital PHILIPS Prod Mon Shot Clr KBD-Universal 1 2 3 4 5 6 7 8 9 0 PHILIPS Prod Mon Shot Clr 1 2 3 4 5 6 7 8 9 RS-485 PHILIPS ALLPLEX VCR A
IntuiKey Keyboard 3.2 Installing the IntuiKey Keyboard | en 13 Connecting to the IntuiKey 1. Refer to Figure 3.8 for details on the input/output connections supplied by the IntuiKey Keyboard. Four connectors are located on the IntuiKey rear panel: (2) RJ-11 connectors, (1) female 9-pin sub-D connector, and a DC power jack. The RJ-11 connectors are labeled as Allegiant and MUX/DVR and the 9-pin sub-D is labeled RS-232 Serial Port.
14 en | Installing the IntuiKey Keyboard IntuiKey Keyboard IntuiKey Keyboard 3 m (10 ft) Data/Power Cable PHILIPS Prod Video Device Mon Shot Clr 1 2 3 4 5 6 7 8 9 0 (See Note) IntuiKey Connection Using Supplied Data Cable IntuiKey Keyboard PHILIPS Prod Mon Shot Clr 1 2 3 4 5 6 7 8 9 Video Device 0 Video Device IN OUT Supplied 3 m (10 ft) Data/Power Cable Video Device IN OUT IN OUT RS-485 (See Note) Multiple Divar Digital Video Recorders or System4 Multiplexers
IntuiKey Keyboard Installing the IntuiKey Keyboard | en 5. 15 After a brief pause (or immediately after the CLR button is pressed) the keyboard performs a brief search for connected devices. NOTICE! On initial power-up, factory reset, or firmware upgrade the IntuiKey displays the i 3.3 Language menu. Select the desired language by pressing the softkey next to the language title.
16 en | Installing the IntuiKey Keyboard 3.3.2 IntuiKey Keyboard Allegiant System Command Scripts for RS-232 Model Keyboards When a keyboard is being connected to an Allegiant’s Console port, or an Allegiant Printer port configured to operate in the Console mode, the Allegiant must be preprogrammed so the port will operate in the RS-232 keyboard mode.
IntuiKey Keyboard Installing the IntuiKey Keyboard | en 17 Keyboard interface connection type Direct to Console port (except LTC 8900) Command: SET-PORT-RS232 0 4 8 0 1 0;_SET_KBD_MODE 01 Direct to Printer port (except LTC 8900) Command: SET-PORT-RS232 4 4 8 0 1 0;_SET_KBD_MODE 4 1 Modem connected to Console port (except LTC 8900) Command: SET-PORT-RS232 0 4 8 0 1 1;_SET_KBD_MODE 0 1 Modem connected to Printer port (except LTC 8900) Command: SET-PORT-RS232 4 4 8 0 1 1;_SET_KBD_MODE 4 1 Direct to Controll
18 en | Installing the IntuiKey Keyboard IntuiKey Keyboard After the script has been entered, download the script into the Allegiant CPU. Reset the system by powering the CPU off/on, or by entering Keyboard User Function 15 on an operating keyboard. The specified port begins to operate in the keyboard mode. The port remains in the keyboard mode unless manually cancelled by entering Ctrl-C several times using Windows HyperTerminal program, operating at 9600 baud.
IntuiKey Keyboard Installing the IntuiKey Keyboard | en Refer to text regarding setup of the Allegiant & LTC 8712 to operate in Allegiant Keyboard mode. Allegiant system main CPU bay BOSCH Prod Mon Shot Clr 1 2 3 4 5 6 7 8 9 0 LTC 8712 Expander 4 3 2 1 User-supplied female 9-pin D connector.
20 en | Installing the IntuiKey Keyboard IntuiKey Keyboard Remember to power the Console Port Expander off/on whenever any changes are made to its internal dipswitches. Connect the data cable supplied with the LTC 8712 Console Port Expander between the unit and the appropriately configured port on the Allegiant. For further details refer to the instructions supplied with the LTC 8712 Port Expander unit.
IntuiKey Keyboard 3.6.1 Installing the IntuiKey Keyboard | en 21 Accessing the Keyboard Control Menu 1. 2. Press PROD to view the Product Selection menu. Press the softkey labeled Keyboard Control. The Keyboard Control softkey can always be found at the very end of the device listings. 3. The Softkey Display shows the Keyboard Control main menu (see Figure 3.10). A review of the Keyboard Control menu options follows.
22 en | Installing the IntuiKey Keyboard Keyboard Test IntuiKey Keyboard Displays a keyboard test screen on the softkey display. Press ENTER to exit the keyboard test mode. As each key is pressed, an indicator displays on the screen. If the joystick is moved, its present variable speed value is displayed. Pan and Tilt ranges LCD Test from 0 to 15; Zoom ranges from 0 to 7. Different patterns are displayed on the softkey display, and the alarm LED flashes.
IntuiKey Keyboard Troubleshooting | en 4 Troubleshooting 4.1 System 1. 23 No text on displays: – Ensure that power is applied to the keyboard through at least one of the following: MUX RJ-11 Cable Allegiant RJ-11 Cable DC Power Supply Jack – It is possible that the LCD contrast has been adjusted to a point that makes the displays unreadable. Pressing MON and CLR simultaneously resets the contrast to a central position for readability.
24 4.3 en | Troubleshooting IntuiKey Keyboard Camera Control 1. Pressing a softkey associated with a camera command does not return the expected response: – Some camera functions are lockable. No softkey is associated with camera command unlock; therefore, unlock the camera commands manually. – The keyboard lists camera commands. Some commands may not be supported by the presently selected camera—see the manual associated with the camera for specific camera function information. 2.
IntuiKey Keyboard A | en 25 Security Information IntuiKey Security Features that should not be changed unintentionally are protected by a general password. This password can be accessed by pressing 1 and 0 simultaneously. If the buttons are not pressed within one (1) second, the command times out. AutoDome Security The AutoDome contains security features to restrict access to its Advanced Menu. To obtain access to the Advanced Menu, enter an Auxiliary Off 90 command.
26 en | F.01U.115.018 | 1.92 | 2008.12 IntuiKey Keyboard Installation Manual Bosch Security Systems, Inc.
Americas Bosch Security Systems, Inc. 850 Greenfield Road Lancaster, Pennsylvania 17601 USA Telephone +1 888-289-0096 Fax +1 585-223-9180 Email: security.sales@us.bosch.com www.boschsecurity.us Europe, Middle East, Africa: Bosch Security Systems B.V. P.O. Box 80002 5600 JB Eindhoven, The Netherlands Phone: + 31 40 2577 284 Fax: +31 40 2577 330 emea.securitysystems@bosch.com www.boschsecurity.