The 'Source/volume' screen also displays level meters (two for a stereo source, one for a
mono source) for a visual indication of the actual signal strength: = low level, = high level,
= overflow.
9.1.5 View version information
In the Enquiry sub-menu (3), version information of the transmitter can be found. This
information should be mentioned in service requests or failure reports.
9.2 Integrus radiators
A radiator consists of two IRED panels. Each IRED panel has an amber and a red indicator LED
which show the status of the radiator panel
9.3 Integrus Receivers
9.3.1 Normal operation
The receiver cannot operate when no headphone is connected. After connecting the
headphone the receiver switches to stand-by mode. Push shortly on the on/off button to
switch the receiver on.
Aux.R Volume:
-31 ... 0 dB
The signal on the Aux. Right input is
available on the monitoring headphone
output.
- None Volume:
-31 ... 0 dB
The monitoring headphone output is
switched off during normal operation,
but is active when the sensitivity of one
of the inputs is being changed.
Menu Item Option Value 1 Value 2 Description
Menu Item Value (read only) Description
3A Serial Number e.g. 19.0.00001 Shows the serial number of the transmitter
board.
3B HW Version e.g. 01.00 Shows the version number of the transmitter
board.
3C FPGA Version e.g. 2.00.00 Shows the version number of the FPGA
software of the transmitter board.
3D FW Version e.g. 1.00.0001 Shows the version number of the transmitter
firmware.
Red LED Amber LED Status
on off Stand-by mode
off on Transmitting
flashing on At switch-on:
Initializing signal equalisationDuring operation:Temperature
protection mode. See section 11.1 .
on on IRED panel failure. See section 11.1 .
NOTICE!
The indicator LEDs are positioned behind the semi-transparent cover and are only visible
when ON.