Configuration Manager 970.129b | V2 | 2014.
Configuration Manager Table of Contents | en 3 Table of Contents 1 Description 4 1.1 Features 4 1.2 Functions 4 2 Installation 5 3 General commands 6 3.1 Language 6 3.2 Create a new BPA file 6 3.3 Revert to factory settings 6 3.4 Print 6 3.5 Export to CSV 7 3.6 Set date and time 7 3.7 Exit 7 4 Programming via microSD card / hard disk drive 8 4.1 Installing the microSD memory card 8 4.
en | Description 1 Description 1.1 Features Configuration Manager The Configuration Manager is a standalone software for – reading/writing the device parameters of Bosch Carephones 6X via serial connection, microSD card or hard disk drive – updating the firmware of Bosch Carephones 6X via serial connection. NOTICE! The programming via serial connection is supported at Bosch Carephones 6X from: 1.2 – Bosch Carephone 61 A2.02 – Bosch Carephone 62 A0.
Configuration Manager 2 Installation | en 5 Installation Download the MSI file package from www.boschsecurity.com. Store the file on your computer, double-click it and follow the steps of the setup wizard. Bosch Security Systems User Manual 970.129b | V2 | 2014.
en | General commands Configuration Manager 3 General commands 3.1 Language Select the language in which you wish to see the Configuration Manager: click on Settings then Language. 3.2 Create a new BPA file Select File and New, a new BPA file for Carephones will be created. You can temporarily name it as you wish, but as soon as you want to upload it to a Carephone, you must name it settings.bpa. 3.3 In the menu Settings, Select the Carephone type.
Configuration Manager 3.5 General commands | en 7 Export to CSV Select File and Export to CSV, all the parameters in the Configuration Manager are exported to a CSV file. 3.6 Set date and time Once the serial connection is established between the Carephone and the Configuration Manager, you can set the date and time values. The Configuration Manager will take the current date and time of the computer running it. 1. In the menu Serial, select Set date and time. 2.
en | Programming via microSD card / hard disk drive 4 Configuration Manager Programming via microSD card / hard disk drive NOTICE! Before you program the Carephone 61/62, you must be familiar with all of the unit's functions. Programming is specifically intended for trained users. Correct programming of the Carephone 61/62 is important for the full function of the unit. Make sure to always read the existing configuration before changing the values of the programming steps. 4.
Configuration Manager 3. Programming via microSD card / hard disk drive | en 9 Take the microSD memory card in the hand and place it with the contacts facing you, as on the drawing. 4. Insert the microSD memory card in the slot and push it until you feel the mechanism has clutched it. 5. Insert the plug of the power supply unit from the socket on the Carephone 61/62. 6. Perform the programming action that you wish. See Section 4.2 Programming procedure via microSD card / hard disk drive, page 10.
en | Programming via microSD card / hard disk drive 4.2 Configuration Manager Programming procedure via microSD card / hard disk drive NOTICE! Before reading from the microSD memory card, make sure that it contains a file. Before writing to the microSD memory card, make sure that it is not write-protected. Existing files with same names will be overwritten.
Configuration Manager Programming via serial connection | en 5 Programming via serial connection 5.1 Serial connection 11 The programming via serial connection is supported at Bosch Carephones 6X from: – Bosch Carephone 61 A2.02 – Bosch Carephone 62 A0.07 For Bosch Carephones 6X that do not support programming via serial connection, the commands Read Parameters and Write Parameters are disabled. You will also get an error message inviting you to update the Carephone. See Section 5.
en | Programming via serial connection 5.3 Configuration Manager Programming procedure via serial connection Once the Carephone is connected to its power supply and to the computer running the Configuration Manager via the serial cable, you can start programming directly the Carephone. Step 1: read the parameters from the Carephone In the menu Serial, click on Read Parameters. The Configuration Manager reads all the parameters from the Carephone and displays them in the different tabs.
Configuration Manager Programming via serial connection | en 13 The Carephone 6X Reflash interface opens: Step 2: select the firmware file Click on the browse button and select the Motorola S19 firmware file. Make sure that the firmware file corresponds to the type of Carephone 6X that you are about to reflash. You have the possibility to keep the user audio announcement message. If so, tick the check-box. Step 3: start the firmware reflash Click on Reflash on the Carephone 6X Reflash interface.
en | Programming via serial connection Configuration Manager CAUTION! Do not disconnect the Carephone until the firmware update is finished! 5.5 Manual firmware reflash If the firmware reflash was interrupted, you must proceed with a manual firmware reflash. Step 1: launch the manual firmware reflash interface In the menu Serial, select Manual firmware reflash.
Configuration Manager Programming via serial connection | en 15 Step 2: bridge the Carephone 6X Open the Carephone 6X that needs a manual firmware reflash, as when replacing the battery. Refer to the user manual of the Carephone 6X. Connect the bridge, using a small slotted screwdriver: Step 3: start the manual firmware reflash Click on Connect on the Manual Carephone 6X Reflash interface. The Carephone is now reconnected to the Configuration Manager. The Carephone 6X Reflash interface opens.
6 en | Programming steps Configuration Manager Programming steps Programming a Carephone 61/62 with the Configuration Manager consists of entering values for the individual steps, numbered 01 to 129. NOTICE! According to the Carephone type, programming steps may not be visible and their values may change. Tab 1 "General" 970.129b | V2 | 2014.
Configuration Manager Programming steps | en 17 03. Radio jamming The Carephone 61/62 sends a technical message to the monitoring centre when a radio signal from another device disturbs it. Check the tick-box to enable this function. 25. Radio transmission monitoring The Carephone 61/62 can monitor the wireless transmitters that are assigned. The wireless transmitters send a signal to the Carephone 61/62 at regular intervals.
en | Programming steps Configuration Manager 33. Speak / Listen command audible You can choose to hear the commands when the Carephone switches between speak and listen in half-duplex mode. Check the tick-box to enable this function. 40. Activity monitor hours and minutes The time for the activity monitor can be set between 15 minutes and 31 hours in steps of 15 minutes. – Enter the number of hours (example: 24 for 24 hours) in the first field.
Configuration Manager Programming steps | en 19 Tab 2 "Call Targets" Bosch Security Systems User Manual 970.129b | V2 | 2014.
en | Programming steps Configuration Manager 11- 19 & 10 Destination number of the emergency call recipient You can enter here the destination number of the emergency call recipient, either a telephone number, or an IP address. 1) Enter the destination number of the emergency call recipient. In the case of a telephone number, register the call number as follows: You can add the following criteria in a telephone call number: B = Dial pause, D = Dial tone detection.
Configuration Manager Programming steps | en 21 Tab 3 "Extended" 23. Waiting time for repeated emergency call An emergency call is repeated to check the arrival of staff until it is acknowledged by pressing the Action button on the Carephone 61/62, or the repeated call is disabled by the monitoring centre. The emergency call is repeated when the defined waiting time is exceeded. – Enter a time between 0 and 99 minutes. 0 = off. Default value is 0. Bosch Security Systems User Manual 970.
en | Programming steps Configuration Manager 26. Callback waiting time The callback function enables the help provider or monitoring centre to terminate an alarm after having acknowledged it. The Carephone must be called back, or the Action button must be pressed, after an alarm has been acknowledged. Define the waiting time after the acknowledgement, during which a call back will be accepted. If this call back waiting time has elapsed, then a new call will be sent by the Carephone.
Configuration Manager Programming steps | en 23 72. Activate output The Carephone 61/62 provides a potential-free relay output with a normally open switch contact.
en | Programming steps Configuration Manager 63. Acoustical feedback for technical failures The Carephone 61/62 can be set to announce technical failures through the LED lamps and the loudspeaker, or through the LED lamps only. – 0 = loudspeaker off – 1 = loudspeaker on. This is the default value. – 2 = loudspeaker on from 7:00 to 21:00 – 3 = an acoustical failure indication (message or beep) is repeated with a pause of 10 seconds until the Action button is pressed.
Configuration Manager Programming steps | en 25 Tab 4 "Function assignement" Bosch Security Systems User Manual 970.129b | V2 | 2014.
en | Programming steps Configuration Manager Function assignment It is possible to link an alarm type to specific call numbers. Each programming step refers to a certain alarm type. – 50. Wireless Transmitter (emergency call with a wireless transmitter) – 51. Emergency call (with the Carephone 61/62) – 52. Fire / intrusion – 53. Repeated emergency call and local confirmation – 54. Sign in / sign out – 55. Service call / direct call.
Configuration Manager Programming steps | en 27 Tab 5 "IP/GSM" 41. DHCP (IP Module) Enable or disable the Carephone 61/62 to use a DHCP service. Check the tick-box to enable this function. 42. IP Address (IP Module) Enter here the IP address of the Carephone 61/62. It should be written in numbers without dots, always with 12 digits. The factory setting is: 192168001100. 43. IP subnet mask (IP Module) Enter here the IP subnet mask of the Carephone 61/62.
en | Programming steps Configuration Manager 44. Gateway (IP Module) Enter here the IP address of the network gateway in case the Carephone 61/62 is connected through this type of device. It should be written in numbers without dots, always with 12 digits. The factory setting is: 192168001001. 45 Automatic test call hours (IP/GSM Module) Program the interval between automatic test calls of the IP Module or GSM Module from the Carephone 62/61 to the monitoring centre in hours.
Configuration Manager Programming steps | en 29 Tab 6 "Professional" 01. Language selection Choose between different languages: 1 = German, 2 = Dutch, 3 = French, 4 = English, 5 = Spanish, 0 is for the synthetic speech disabled mode. 29. Hear/speech impaired This is dedicated to users with speaking or hearing difficulties. Once a connection to the monitoring centre is established, the signals advise the user that he or she is through to the monitoring centre (the centre is listening).
en | Programming steps Configuration Manager Tab 7 "RF detector" 970.129b | V2 | 2014.
Configuration Manager Programming steps | en 31 RF detector registering and assigning: Enter the code number for each transmitter (91, 92, etc.
en | Programming steps Configuration Manager You have also access to extended programming features: In steps 121, 122, etc, select the activation start and end time for each RF detector, in steps of 15 minutes. In steps 201, 202, etc, select the custom alarm type for each RF detector. It must be a 3-digit value from 0 to 999. Select also the custom event handler: – emergency event (personal). Choose this setting in the case of a person triggering the alarm. Notice: this resets the activity monitor.
Configuration Manager | en A Appendix A.1 Technical specifications 33 Storage type free definable name on the computer OS Windows XP, 7 & 8 Available languages English, German, French, Dutch microSD card 32 GB maximum capacity serial connection - from Bosch Carephone 61 A2.02 programming supported - from Bosch Carephone 62 A0.07 Recommended - Bosch serial programming cable APD 9 poles connectors (commercial type number CRS-CP-SPC-APD9P, SAP number F.01U.140.
en | A.
Bosch Security Systems Robert-Bosch-Ring 5 85630 Grasbrunn Germany www.boschsecurity.