Specifications

D5200 Programmer Operation Manual
Page 36
© 1991-1995 Radionics
74-06176-000-B 9/95
A-5200-030-360
5. Mode prompt entry:
To transfer a handler to internal Disk A: Press the SPACE bar until the TELCOA
selection is displayed.
To transfer a handler to removable RAM Disk B: Press the SPACE bar until the
TELCOB selection is displayed.
6. Press the white ENTER key. The programmer clicks as it dials out, and the message
WAITING for CARRIER is momentarily displayed, followed by the message WAITING
for CONNECT to Update System is displayed. When this handler request is detected
by the Update System, the Update System transfers the requested handler. The
progress of the handler reception is displayed on the programmer (see Figure 26). If the
transfer is successful, the message UPDATE SUCCESSFUL is displayed. The cursor
returns to the UPDATE menu. To update additional handlers, repeat steps 2 through 6.
If the transfer is not successful, the message UPDATE FAILURE is displayed. If the
handler requested by the programmer was not available in the Update System, the
message HANDLER NOT FOUND is displayed.
7. To return to the Product Handlers level, press the red EXIT GROUP key.
RECEIVING 7112
0% 100%
Block:xxx:
Figure 26: "RECEIVING PROGRAMMER" UPDATE PROGRESS
Programmer Tip – Updating Multiple Programmers
The time required to updatehandlers in a programmer depends upon the interfaced
used (see Figure 23). Since it is much quicker to update a D5200 via the RS-232 serial
interface, Radionics recommends updating only the first programmer via the phone
(Telco) lines, and updating additional programmers from the first programmer via the
RS-232 interface (see "Updating Via RS-232" on the following pages).
TELCO A
TELCO B