Installation Guide
19
5.
Insert the flat washer. 
6.
Attach the red wire to the left junction block terminal 
using one of the hexagonal nuts. 
7.
Attach the white wire to the center junction block 
terminal using one of the hexagonal nuts. 
8.
Attach the black wire to the right junction block 
terminal using one of the hexagonal nuts. 
9.
Properly secure strain relief. 
9 WARNING
WARNING
The strain relief provided with your range cord 
must be installed correctly.
10.
Tighten all connections securely and replace terminal 
block cover. 
Note: Do not plug in the range at this time.
Connecting the three-wire flexible conduit
The four-wire connection is preferred, but where local 
codes and ordinances permit grounding through neutral 
and/or conversion to four-wire is impractical, the unit can 
be connected to the power supply via a three-wire 
connection.
1.
Disconnect the electrical power at the breaker box. 
Remove the terminal block cover to expose the 
terminal block. 
2.
Insert the power supply cable into the terminal block 
through the bottom hole. 
3.
Insert the flat washer. 
4.
Attach the red wire to the left junction block terminal 
using one of the hexagonal nuts. 
5.
Attach the white wire to the center junction block 
terminal using one of the hexagonal nuts. 
6.
Attach the black wire to the right junction block 
terminal using one of the hexagonal nuts. 
7.
Properly secure strain relief. 
9 WARNING
WARNING
The strain relief provided with your range cord 
must be installed correctly.
8.
Tighten all connections securely and replace terminal 
block cover. 
Note: Do not plug in the range at this time.