4.
Screw the adjustable feet into the mounting holes on 
the underside of the appliance.
Note: If the appliance needs to be moved again, 
screw the adjustable feet in fully.
5.
Carefully move the appliance back on the feets.
6.
Turn the adjustable feet to align the appliance.
Note: Measure the installation height of the cabinetry 
and adjust appliance height accordingly prior to 
placing appliance in cabinetry.
Connect Gas Supply
The appliance is shipped from the factory for use with 
natural gas at a pressure of 5" of the water column. 
When checking for proper operation of the regulator, the 
inlet pressure must be at least 1" greater than the 
operating (manifold) pressure above. When used with 
natural gas, the pressure supplied to the regulator must 
be between 6" and 10,5" of the water column.
To convert the appliance to propane gas see 
“Conversion to propane gas (LPG)”. A qualified 
technician or installer must do the conversion. 
Use a flexible gas pipe with a length of at least 5 ft 
(1.5 m).
The gas inlet to the unit is located at the right rear of the 
appliance.
Install the pressure regulator (supplied with unit) to gas 
inlet. Postion the gasket (supplied with unit) in between 
the inlet and the regulator. Position the regulator to have 
it cap D (~  Page 23) easily accessible. Turn the nut on 
gas inlet to hand tighten plus 1/3 turn.
Install the gas pipe to the regulator using Teflon tape or 
pipe-joint compound (resistant to propane gas and 
natural gas). Turn to hand tighten plus 1/3turn. Do not 
exceed 1 turn for alignment, to prevent possible damage 
to the gas pressure regulator.
Check inlet fittings and regulator for leaks.
* Attached to the appliance.
9 WARNING
Do not attempt any adjustment of the pressure 
regulator, except when converting to propane. 
Adjustments could lead to leaks or cause incorrect 
gas pressure to the appliance.
Side and Back View Gas Cooker Installation
Gas Location
Connect the gas supply line to the unit pressure 
regulator using a 1/2” flex gas line connector between 
manual shut-off valve and pressure regulator. A metal 
flex line or fixed metal pipe shall be used to connect gas 
to the appliance. If a metal gas line cannot be used, 
consult your local certified electrician or local electric 
codes for proper grounding.
A Gas connection
B Electrical connection
%
$