Installation Guide
10
Choose one of the following built-in configurations.
Installation allowed only with non combustible back 
wall
▯ Option 1: A >= 12'' (305 mm) and B >= 28'' (711 mm)
▯ Option 2: A >= 28'' (711 mm) and B >= 12'' (305 mm)
* Clearances from non-combustible materials are not 
part of the ANSI Z21.1scope and are not certified by 
“Intertek”. Clearances of less than 3'' (76 mm) should be 
approved by the local codes and/or by the local authority 
having jurisdiction.
Island Installation (applicable both with non 
combustible back wall and combustible back wall)
▯ Option 1: A >= 12'' (305 mm) and B >= 28'' (711 mm)
▯ Option 2: A >= 28'' (711 mm) and B >= 12'' (305 mm)
* purchased separately
** Clearances from non-combustible materials are not 
part of the ANSI Z21.1scope and are not certified by 
“Intertek”. Clearances of less than 3'' (76 mm) should be 
approved by the local codes and/or by the local authority 
having jurisdiction.
Low Backguard Installation (applicable both with non 
combustible back wall and combustible back wall)
▯ Option 1: A >= 12'' (305 mm) and B >= 28'' (711 mm)
▯ Option 2: A >= 28'' (711 mm) and B >= 12'' (305 mm)
* purchased separately
** Clearances from non-combustible materials are not 
part of the ANSI Z21.1scope and are not certified by 
“Intertek”. Clearances of less than 3'' (76 mm) should be 
approved by the local codes and/or by the local authority 
having jurisdiction.
Technical Data
30” (5burners):
36” (6burners):
%
$
PLQ
%
$
Total connected load electric 1 A (120 W)
Total connected load gas 
(natural gas)
48,000BTU/h 
 (14.1 kW)
Total connected load gas 
(propane gas)
48,000BTU/h 
 (14.1 kW)
Total connected load electric 1 A (120 W)
Total connected load gas 
(natural gas)
63,000BTU/h 
 (18.4 kW)
Total connected load gas 
(propane gas)
63,000BTU/h 
 (18.4 kW)
%
$