Assembly Instructions
Table Of Contents
- _
- en-us
- Table of contents
- 1 IMPORTANT SAFETY INSTRUCTIONS
- 1.1 Safety definitions
- 1.2 General information
- 1.3 General safety instructions
- 1.4 Appliance handling safety
- 1.5 Installation location
- 1.6 Safety codes and standards
- 1.7 Electrical safety
- 1.8 Gas safety
- 1.9 Propane gas installation
- 1.10 Conversion to Liquified Petroleum gas
- 1.11 Ventilation recommendations
- 1.12 High altitude installation
- 1.13 State of California Proposition 65 Warnings
- 1.14 Transport
- 2 Before you begin
- 3 Removing the packaging
- 4 Installation requirements
- 5 Prior to installation
- 6 Electrical connection
- 6.1 Electrical requirements
- 6.2 Electrical connection for gas models
- 6.3 Electrical connection for dual fuel models
- 7 Connecting the gas supply
- 8 Installing the range into the cabinets
- 9 Testing the operation
- 10 Customer service
- fr-ca
- Table des matières
- 1 IMPORTANTES CONSIGNES DE SÉCURITÉ
- 1.1 Définitions des termes de sécurité
- 1.2 Indications générales
- 1.3 Consignes générales de sécurité
- 1.4 Manipulation sécuritaire des appareils
- 1.5 Lieu d'installation
- 1.6 Codes et normes de sécurité
- 1.7 Sécurité électrique
- 1.8 Sécurité des gaz
- 1.9 Installation au gaz propane
- 1.10 Conversion au gaz de pétrole liquéfié
- 1.11 Recommandations de ventilation
- 1.12 Installation à haute altitude
- 1.13 Mises en garde conformément à la proposition 65 de l'État de Californie
- 1.14 Transport
- 2 Avant de commencer
- 3 Retirer l'emballage
- 4 Exigences d'installation
- 5 Avant l'installation
- 6 Raccordement électrique
- 6.1 Exigences électriques
- 6.2 Raccordement électrique pour les modèles à gaz
- 6.3 Raccordement électrique pour les modèles bi-énergie
- 7 Raccordement de d’alimentation en gaz
- 8 Installer la cuisinière dans les armoires
- 9 Opération d’essai
- 10 Service à la clientèle
- es-mx
- Tabla de contenidos
- 1 INSTRUCCIONES DE SEGURIDAD IMPORTANTES
- 1.1 Definiciones de seguridad
- 1.2 Indicaciones generales
- 1.3 Instrucciones generales de seguridad
- 1.4 Seguridad de manejo del aparato
- 1.5 Lugar de instalación
- 1.6 Códigos y normas de seguridad
- 1.7 Seguridad eléctrica
- 1.8 Seguridad de los aparatos de gas
- 1.9 Instalación con gas propano
- 1.10 Conversión a gas licuado del petróleo
- 1.11 Recomendaciones de ventilación
- 1.12 Instalación a gran altitud
- 1.13 Advertencias en virtud de la Proposición 65 del estado de California
- 1.14 Transporte
- 2 Antes de empezar
- 3 Retirar el embalaje
- 4 Requisitos de instalación
- 5 Antes de la instalación
- 6 Conexión eléctrica
- 6.1 Requisitos eléctricos
- 6.2 Conexión eléctrica para modelos de gas
- 6.3 Conexión eléctrica para modelos de doble combustible
- 7 Conectar el suministro de gas
- 8 Instalación del electrodoméstico en los gabinetes
- 9 Comprobación del funcionamiento
- 10 Servicio de atención al cliente
en-us Electrical connection
12
3. Remove the top nut (has an attached locking washer)
from each post.
Note:DO NOT remove the second nut/washer on each
post; these must stay in place to anchor the internal
wiring attached to the terminal block.
4. Remove the green grounding screw from the lower
end of the grounding strap.
5. Remove the grounding strap from the center post of the
terminal block.
6. Rotate the grounding strip so that the wide end is up
and align the hole with the grounding hole below the ter-
minal block.
7. Use the green grounding screw to attach the green
wire on top of the grounding strap.
8. Tighten the grounding screw firmly, but do not over-
tighten.
9. Attach the red wire to the left terminal using one of the
nut/washers removed previously.
r Red
w White
g Green
b Black
10. Attach the white wire to the center terminal using one of
the nut/washer parts.
11. Attach the black wire to the right junction block terminal
using one of the nut/washer parts.
12. Tighten all connections securely and replace terminal
block cover.
13. Properly secure strain relief.
→
"Routing the electrical cord", Page11
Note:DO NOT plug in the range at this time.
Installing a three-wire connection
Alternate method
Note:The four-wire connection (above) is preferred, but
where local codes and ordinances permit grounding
through the neutral and where conversion to four-wire is
impractical, the unit may be connected to the power sup-
ply via a three-wire connection.
1. Disconnect electrical power at breaker box.
2. Remove the terminal block cover to expose the terminal
block.