Installation Manual

Page 11
7. Connect green (or bare) ground wire from home power
supply to yellow-green ground wire (E) in terminal box
using UL listed wire connectors.
B
A
C
D
E
A Installation pipe
B Cable connector listed in UL
C Black wires
D White wires
E Yellow-green ground wire
8. Tighten strain relief screw.
9. Install the junction box cover.
10. Plug the cable connector located on the top of the
junction box.
Attaching flue duct
Hidden surfaces may have sharp edges. Use caution
when reaching behind or under appliance.
1. Removetheprotectivefoilfrombothueducts.
2. Pushoneueductintotheother.
Notes
To prevent scratches, lay paper over the edges of
thelowerueducttoprotectthesurface.
Forductedoperation,turntheupperueductso
that the ventilation slots point downward.
3. Remove the protective foil from the extractor hood.
4. Placeueductsontheappliance.
5. Pushtheinnerueductupwardsandattachittothe
angle brackets on the left and right.
6. Screwtheueducttothesidesoftheanglebracket
using two screws.
AB
7. Fastenthelowerpartoftheueductusingtwo
screws.
8. Removetheprotectivepaperfromthelowerueduct.
9. Installmetal-meshgreaselter.
Removing the appliance
1. Removethemetal-meshgreaselter.
2. Loosentheueduct.
3. Disconnect the appliance from the power supply.
4. Loosen the exhaust air lines.
5. Loosen screws for fastening the appliance.
6. Remove the appliance.