Technical data
Table Of Contents
- Table of contents
- 1 Key to symbols and safety instructions
- 1.1 Explanation of symbols
- 1.2 Safety instructions
- 2 About the appliance
- 2.1 Designated use
- 2.2 EU Declaration of Conformity
- 2.3 Data plate
- 2.4 Standard delivery
- 2.5 Accessories
- 2.6 Tools, materials and miscellaneous parts
- 2.7 General information on energy use and heat production
- 2.8 Function description of the hybrid manager
- 2.9 Handling circuit boards
- 2.10 Refrigerant circuit
- 2.11 Combi boiler with serial buffer tank, bypass valve and unmixed heating circuit
- 2.12 System boiler with serial buffer tank, bypass valve and unmixed heating circuit
- 2.13 Combi boiler with serial buffer tank, bypass valve, unmixed heating circuit and independently controlled mixed heating circuit
- 2.14 System boiler with serial buffer tank, bypass valve, unmixed heating circuit and independently controlled mixed heating circuit
- 2.15 Overview of components
- 2.16 Dimensions
- 2.17 Technical Data
- 3 Regulations
- 4 Transport
- 5 Mounting and installation
- 5.1 Preparing for installation
- 5.2 System component configuration
- 5.3 Pre-installing pipes
- 5.4 Mounting the hybrid manager
- 5.5 Installing the external unit
- 5.6 Installing the refrigerant circuit
- 5.7 Making the electrical connection
- 5.8 Installing the outside temperature sensor
- 5.9 Setting the DIP switches of the external unit
- 6 Commissioning
- 6.1 Before commissioning
- 6.2 Commissioning the system for the first time
- 6.2.1 Providing the external unit with a power supply ahead of commissioning
- 6.2.2 providing the external unit with a power supply during commissioning
- 6.2.3 Connecting the CANBUS cable to the hybrid manager unit
- 6.2.4 Making the power supply connection
- 6.2.5 Switching on the hybrid system
- 6.2.6 Connecting the programming unit to the hybrid control module
- 6.2.7 Connecting the heat source to the hybrid manager
- 6.2.8 Communication error from External unit on initial power ON of External Unit and Hybrid Manager
- 6.2.9 Adjusting the Hybrid manager circulating pump in the hybrid manager
- 6.2.10 System with series buffer tank
- 6.2.11 Venting the hybrid manager
- 6.2.12 Setting the bypass valve
- 6.2.13 Setting parameters for optimising energy use and costs of the hybrid system
- 6.2.14 Explanation of the parameters for energy and cost optimization of the hybrid system (control strategy)
- 6.2.15 Control Strategy: Option CO2 Optimised and co2 :cost mix
- 6.2.16 Control Strategy: Co2 optimised (environmental factors)
- 6.2.17 Control Strategy: CO2: Cost mix
- 6.2.18 Control Strategy: Option changeover temperature
- 6.2.19 Control Strategy: Cost optimised
- 6.2.20 Control strategy: hydraulic connection
- 6.2.21 Control strategy: Delay time for boiler heating
- 6.2.22 Control strategy: Temperature diff for boiler switch ON
- 6.2.23 Setting parameters at the hybrid control module
- 6.2.24 Commissioning of the air to water heat pump at outside temperatures outside the standard operating range
- 6.2.25 Informing the customer and handing over the technical documents
- 7 Operation
- 8 Environmental protection/disposal
- 9 Inspection and maintenance
- 10 Faults
- 10.1 Faults that are not displayed
- 10.2 Displayed faults
- Overview of internal hybrid fault indicators locations
- 10.2.1 Fault displays on the hybrid control module
- 10.2.2 Check temperature sensor of hybrid manager
- 10.2.3 Faults of the FW200 programming unit
- 10.2.4 Fault display on the FW 200 weather-compensated controller at user level
- 10.2.5 Fault display on the rear of the hybrid manager
- 10.2.6 External unit faults
- 10.2.7 Check components
- 10.2.8 DC fan motors/check PCB
- 10.2.9 Check external unit temperature sensor
- 10.2.10 Check linear expansion valves (LEV)
- 11 Replace components
- 11.1 Pumping refrigerant back into the external unit
- 11.2 Removing the casing from the external unit
- 11.3 Replacing the fan motor
- 11.4 Replacing the PCB housing
- 11.5 Replacing PCBs
- 11.6 Replacing faulty temperature sensors TH3, TH6 or TH33
- 11.7 Replacing outside temperature sensor TH7
- 11.8 Replacing temperature sensors TH4 and TH32
- 11.9 Fitting and removing the linear expansion valve
- 11.10 Removing the transformer (ACL)
- 12 Filling the refrigerant circuit
- 13 Appendix
- 13.1 Cost weighting electricity price — gas price
- 13.2 System wiring (heatronic III boiler connections) with a bypass valve and one unmixed heating circuit
- 13.3 System wiring (CUS boiler connections) with a bypass valve and one unmixed heating circuit
- 13.4 Wiring to PCB in the external unit (heat pump)
- 13.5 Controller circuit board in external unit
- 13.6 Alternative pipe work lengths and T
- 14 General details
- 15 Assembly and installation report for the installer
- 16 Commissioning report for the commissioning engineer

APPENDIX
6 720 803 687 (2012/11)82
13 APPENDIX
13.1 COST WEIGHTING ELECTRICITY PRICE — GAS PRICE
Electricity price [P/kWh]
10.0-10.9
11.0-11.9
12.0-12.9
13.0-13.9
14.0-14.9
15.0-15.9
16.0-16.9
17.0-17.9
18.0-18.9
19.0-19.9
20.0-20.9
21.0-21.9
22.0-22.9
23.0-23.9
24.0-24.9
25.0-25.9
26.0-26.9
27.0-27.9
28.0-28.9
29.0-29.9
30.0-30.9
Gas price [P/kWh]
3.0-3.9 2.8 3.0 3.3 3.5 3.8 4.1 4.3 4.6 4.9 5.1 5.4 5.7 5.9 6.2 6.4 6.7 7.7 7.2 7.5 7.8 8.8
4.0-4.9 2.1 2.3 2.5 2.7 3.0 3.2 3.4 3.6 3.8 4.0 4.2 4.4 4.6 4.8 5.0 5.2 5.4 5.6 5.8 6.0 6.2
5.0-5.9 1.7 1.9 2.1 2.2 2.4 2.6 2.7 2.9 3.1 3.2 3.4 3.6 3.7 3.9 4.1 4.2 4.4 4.6 4.7 4.9 5.1
6.0-6.9 1.5 1.6 1.8 1.9 2.0 2.2 2.3 2.5 2.6 2.7 2.9 3.0 3.2 3.3 3.4 3.6 3.7 3.9 4.0 4.2 4.3
7.0-7.9 1.3 1.4 1.5 1.6 1.8 1.9 2.0 2.1 2.3 2.4 2.5 2.6 2.7 2.9 3.0 3.1 3.2 3.3 3.5 3.6 3.7
8.0-8.9 1.1 1.2 1.3 1.4 1.6 1.7 1.8 1.9 2.0 2.1 2.2 2.3 2.4 2.5 2.6 2.7 2.8 3.0 3.1 3.2 3.3
9.0-9.9 1.0 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2.0 2.1 2.2 2.3 2.4 2.4 2.5 2.6 2.7 2.8 2.9
10.0-109 0.9 0.9 1.1 1.2 1.3 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2.0 2.0 2.1 2.2 2.3 2.4 2.5 2.6 2.6
11.0-11.9 0.8 0.9 1.0 1.1 1.1 1.2 1.3 1.4 1.5 1.5 1.6 1.7 1.8 1.9 1.9 2.0 2.1 2.2 2.3 2.3 2.4
12.0-12.9 0.8 0.8 0.9 1.0 1.1 1.1 1.2 1.3 1.3 1.4 1.3 1.6 1.6 1.7 1.8 1.9 1.9 2.0 2.1 2.2 2.2
13.0-13.9 0.7 0.8 0.8 0.9 1.0 1.0 1.1 1.2 1.2 1.3 1.2 1.4 1.5 1.6 1.7 1.7 1.8 1.9 1.9 2.0 2.1
14.0-14.9 0.7 0.7 0.8 0.8 0.9 1.0 1.0 1.1 1.2 1.2 1.2 1.3 1.4 1.5 1.5 1.6 1.7 1.7 1.8 1.9 1.9
15.0-15.9 0.6 0.7 0.7 0.8 0.9 0.9 1, 1.0 1.1 1.1 1.1 1.3 1.3 1.4 1.4 1.5 1.6 1.6 1.7 1.7 1.8
16.0-16.9 0.6 0.6 0.7 0.7 0.8 0.9 0.9 1.0 1.0 1.1 1.0 1.2 1.2 1.3 1.4 1.4 1.5 1.5 1.6 1.6 1.7
Table 47 Example: Cost weighting electricity price — gas price