Technical data

Table Of Contents
ABOUT THE APPLIANCE
6 720 803 687 (2012/11)8
2.10 REFRIGERANT CIRCUIT
Fig. 6 Refrigerant circuit
[A] Refrigerant flow during defrosting
[B] Refrigerant flow during heating
[1] Heat exchanger / evaporator
[2] Temperature sensor TH6 on the pipe to the evaporator
[3] TH7 outside temperature sensor
[4] Temperature sensor TH3 on pipe work for liquid refrigerant
[5] Distributor
[6] Temperature sensor TH33 on pipe work for liquid refrigerant
[7] Dirt trap
[8] Linear expansion valve LEV-A
[9] Liquid receiver
[10] Linear expansion valve LEV-B
[11] Shut-off valve
[12] Connection for liquid refrigerant
[13] Connection for gaseous refrigerant
[14] Shut-off valve with Schraeder valve
[15] 4-way valve
[16] Charging connection
[17] High pressure switch 63H
[18] Silencer
[19] Temperature sensor TH4 for hot gas
[20] Temperature sensor TH32 on compressor casing
[21] Compressor
9 8 7
A
B
7
7
1 2
3
4
5
6
6 720 646 970-04.3ITL
14
12
13
11 10
15 16
17
18
19
20
21
18