10.2 DISPLAYED FAULTS
External unit faults are signalled by LEDs on the PCB in the external unit
Fig. 64, page 60.
Hybrid manager faults are displayed on the hybrid control module
Fig. 61, page 56 and Fig. 63, page 59.
Hybrid system faults are displayed on the FW200 programming unit
Fig 62, page 57.
Identify the fault and have it rectified.
Hold down the Back button on the hybrid control module for
5 seconds to restart the hybrid control module.
OVERVIEW OF INTERNAL HYBRID FAULT INDICATORS LOCATIONS
Fig. 60 Overview internal hybrid components fault indicators locations
[1] Error indicator (hybrid manager)
[2] Display (hybrid manager)
[3] FW200 display
[4] Error indicator (hybrid manager)
10.2.1 FAULT DISPLAYS ON THE HYBRID CONTROL MODULE
Error states are indicated as operating codes by the hybrid control
module.
Display the current error code with Back button [7].
The current operating code is displayed on the right hand side of the
large display [6] (Fig. 61, page 56).
DANGER: Danger to life through electric shock!
Prior to working on the electrical section, isolate the
power supply (230 V AC) (fuse for the external unit,
hybrid manager and heat source) and secure against
unintentional reconnection.
WARNING: Risk of injury and damage through incorrect
troubleshooting.
Have troubleshooting carried out only by a competent
person.
Permit only qualified refrigeration engineers (F gas
qualification), whose company holds a valid F gas
certificate) to work on the refrigerant circuit.
For an explanation of error codes, see table 35,
from page 59.