DX4010V2 Installation Instructions EN RS-232/USB Serial Interface Module
DX4010V2 | Installation Instructions | Trademarks Trademarks • 2 BlackBox® is either a registered trademark or a trademark of BlackBox Corporation in the United States and/or other countries. Bosch Security Systems, Inc.
DX4010V2 | Installation Instructions | Contents Contents 1.0 2.0 3.0 4.0 5.0 5.1 5.2 5.3 6.0 7.0 8.0 9.0 9.1 General Information ....................................4 Specifications ..............................................4 Installation Standards .................................4 Wiring........................................................... 5 DX4010V2 Jumper Pin Settings ................ 6 Enable LED Jumper Pins (P2) ..................... 6 DB9 Ground Enable Pins (P1) .....................
DX4010V2 | Installation Instructions | 1.0 General Information 1.0 General Information The DX4010V2 is a data terminal equipment (DTE) configured RS-232/USB serial device interface. This module is designed to operate with compatible control panels. It connects to the control panel through the Option or SDI data bus.
DX4010V2 | Installation Instructions | 4.0 1. Disconnect power to the control panel by unplugging the transformer and removing the red battery lead. 2. Remove screws from enclosure cover to access the DX4010V2 board. 3. Connect circuit wiring and install jumper pins. Refer to Section 4.0 Wiring on page 5. 4. Replace enclosure cover. 5. Connect a serial cable to the serial device. Refer to Section 7.0 DB9 DTE RS-232 Connector (P6) on page 10. 6. Reapply power to the control panel.
DX4010V2 | Installation Instructions | 5.0 DX4010V2 Jumper Pin Settings Figure 5 shows a parallel printer connected to the serial output of the DX4010V2. This type of connection requires the use of a serial to parallel converter, such as the BlackBox PI045A serial to Centronics parallel converter cable. The cable is available from BlackBox® (www.blackbox.com).
DX4010V2 | Installation Instructions | 6.0 5.3 Address DIP Switches The address DIP switches are used to assign an address to the DX4010V2. Refer to Table 3 on page 8 for DIP switch option bus address settings. Refer to Table 4 on page 9 for DIP switch SDI bus address settings. Refer to Figure 7 for proper DIP switch orientation. Figure 7: DIP Switch Location and Orientation LED Rx Tx BUS 1 Tx Rx SER Remote Programming Direct Connection 6.
DX4010V2 | Installation Instructions | 6.0 Remote Programming Direct Connection Table 3: Option Bus Address DIP Switch Settings Some automation software packages might require that you restart the application if USB connection is lost during use.
DX4010V2 | Installation Instructions | 6.
DX4010V2 | Installation Instructions | 7.0 DB9 DTE RS-232 Connector (P6) 7.0 DB9 DTE RS-232 Connector (P6) Figure 8: DB9 Connector Layout 1 The DX4010V2 serial port is wired as a DTE device. • If the connected device is a data carrier equipment (DCE) device (most common, such as an external modem), use a straight through 9-pin to 9-pin, or (DTE to DCE) 9-pin to 25-pin cable.
DX4010V2 | Installation Instructions | 8.0 RJ-16 Data Bus Connector (P3) 2. Click Run. Figure 11: Security Warning 8.0 RJ-16 Data Bus Connector (P3) Figure 9: P3 Connector LED Rx Tx BUS Tx Rx SER 1 P2 P1 P3 DB9 GND ENABLE 1- RJ-16 data bus connector (P3) For remote programming connection, use one of the two cables supplied: RJ-16 to molex for control panels with the data bus provided on a header (such as the D6412, DS7240, or the GV2 control panels).
DX4010V2 | Installation Instructions | 9.0 5. Click Next to accept the default location. Figure 14: Destination Location USB Data Bus Connector 8. Select Launch the CP210x VCP Driver Installer, then click Finish. Figure 17: Installation Complete 6. Click Install. Figure 15: Ready to Install 9. Click Install. Figure 18: USB Driver Installer 10. The program will look for the file location. Figure 19: Scanning 7. The drivers install. Figure 16: Setup Status 11.
DX4010V2 | Installation Instructions | 9.0 10.0 Configuring the DX4010V2 Before configuring the DX4010V2, be sure to connect the DX4010V2 to the USB port and the control panel. Be sure that the address is correct and that the red LEDs are flashing (if enabled). USB Data Bus Connector 4. Expand Ports. 5. Note the COM port number, in parentheses, after Silicon Labs CP210x USB to UART Bridge. In this example, the COM port number is 3. Figure 22: Device Manager 1.