Extractor hood [en] Instructions for installation and use
Ú Table of contents e[nuoIrs]acitlfde INSTRUCTION MANUAL............................................................ 2 Important safety information................................................ 2 Environmental protection ..................................................... 4 Environmental protection..............................................................4 Operating modes................................................................... 4 Exhaust air mode .........................................
Danger of suffocation! Packaging material is dangerous to children. Never allow children to play with packaging material. Danger of death! Risk of poisoning from flue gases that are drawn back in. Always ensure adequate fresh air in the room if the appliance is being operated in exhaust air mode at the same time as room air-dependent heat-producing appliance is being operated. In any case, consult your responsible Master Chimney Sweep.
Risk of injury! ■ Components inside the appliance may have sharp edges. Wear protective gloves. ■ Items placed on the appliance may fall down. Do not place any objects on the appliance. ■ The light emitted by LED lights is very dazzling, and can damage the eyes (risk group 1). Do not look directly into the switched on LED lights for longer than 100 seconds. Risk of electric shock! ■ A defective appliance may cause electric shock. Never switch on a defective appliance.
Operation These instructions apply to several appliance variants. It is possible that individual features are described which do not apply to your appliance. Note: Switch on the extractor hood when you start cooking and switch it off again several minutes after you have finished cooking. This is the most effective way of removing the kitchen fumes.
Intensive setting Control panel model 3 You can use the intensive setting if there is a large build-up of odours and fumes/vapours. Control panel Press the + button when the fan is at setting „. ERRVW The intensive boost setting‚ is activated. Pressing the + button again activates the intensive boost ƒsetting. After approx. six minutes, the electronics automatically reduce the fan to a lower setting .
1. When the fan is switched off, press the 1 button and hold it for approx. 4 seconds. The setting is displayed. 2. Press the + or - button to change the setting of the sensor control. In addition, the corresponding symbol appears in the display: ■ Metal mesh grease filter: # ■ Activated carbon filter: ’# approx. 4 seconds. If you have not yet done so, the metal mesh grease filters should be cleaned or the activated carbon filter changed now.
Cleaning the metal mesh grease filters Removing metal mesh grease filter : Risk of fire! 1. Open the lock and fold down the metal grease filter. While Grease deposits in the grease filter may catch fire. Clean the grease filter at least every 2 months. Never operate the appliance without the grease filter. 2. Take the metal grease filter out of the holder. doing this, place the other hand under the metal grease filter. Notes ■ Do not use any aggressive, acidic or alkaline cleaning agents.
Trouble shooting Malfunctions often have simple explanations. Please read the following notes before calling the after-sales service. : Risk of electric shock! Replacing bulbs : Risk of electric shock! Incorrect repairs are dangerous. Repairs may only be carried out and damaged power cables replaced by one of our trained after-sales technicians. If the appliance is defective, unplug the appliance from the mains or switch off the circuit breaker in the fuse box. Contact the after-sales service.
Accessories for circulating-air mode (not included in the delivery) Notes ■ Follow the installation instructions supplied with the accessories. ■ Basic equipment: CleanAir recirculation module - wide 7 For appliances with an additional internal filter, only the CleanAir recirculation module can be used.
INSTALLATION INSTRUCTIONS Installation instructions PLQ PP PD[ PP [ PLQ PP [ PP PLQ PP [ [ [ [ [ [ [ ■ ■ ! PP ■ This appliance is installed on the wall. Follow the enclosed installation instructions for additional special accessories (e.g. for circulating-air mode). The surfaces of the appliance are sensitive. Avoid damaging them during installation. ! PP : Important safety information Read these instructions carefully.
Room air-dependent heat-producing appliances (e.g. gas, oil, wood or coaloperated heaters, continuous flow heaters or water heaters) obtain combustion air from the room in which they are installed and discharge the exhaust gases into the open air through an exhaust gas system (e.g. a chimney). In combination with an activated vapour extractor hood, room air is extracted from the kitchen and neighbouring rooms - a partial vacuum is produced if not enough fresh air is supplied.
General information Exhaust air mode : Risk of death! Risk of poisoning from flue gases that are drawn back in. The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventilate installation rooms that contain heating appliances. If the exhaust air is to be conveyed into a non-functioning smoke or exhaust gas flue, you must obtain the consent of the heating engineer responsible. ■ Flat ducts should have no sharp deflections.
Installation Attaching and aligning the appliance 1. Screw on the fixing bracket for the flue duct. ¨ 1. Initially remove the protective foil from the back of the $ appliance and, following installation, remove the foil completely. 2. When attaching the appliance, ensure that it engages firmly with the brackets. « 3. Align the appliance horizontally by turning the brackets. If required, the appliance can be moved to the right or left. ¬ [ ' ( 2.
Removing the safety caps If the safety caps must be removed, use a flat screwdriver. Attaching the flue duct : Risk of injury! From sharp edges during installation. Always wear protective gloves while installing the appliance. 1. Separate the flue ducts. To do this, remove the adhesive tape. 2. Remove the protective foil from both flue ducts. 3. Push one flue duct into the other.
Robert Bosch Hausgeräte GmbH Carl-Wery-Straße 34 81739 München Germany www.bosch-home.