Installation Manual

Table Of Contents
26 en | Connection DSA E-Series (E2800 12-bay)
2018.02 | V1 | DOC Installaton manual Bosch Sicherheitssysteme GmbH
1
5
2
3
7
4
6
98
1 Private network 2 Management station or personal
computer
3 Local Area Network (LAN) 4 Switch or hub
5 Dual controller unit 6 ControllerA
7 ControllerB 8 Management port1 (Ethernet)
Note: Used as default.
9 Management port2 (Ethernet)
Note: Reserved for maintenance
operations if the hardware contains a
second Ethernet port.
Notice!
Ethernet port 2 should be reserved for maintenance operations if your hardware contains a
second Ethernet port.
5.4 Connecting the units to the power supply
To connect the controller unit and the expansion units to the power supply:
1. Confirm that the two power switches on the controller unit are off.
Note: If you have expansion units, confirm that their power switches are off.