Installation Manual

Table Of Contents
22 en | Installation DSA E-Series (E2800 12-bay)
2018.02 | V1 | DOC Installaton manual Bosch Sicherheitssysteme GmbH
About this procedure
The following figure shows the operator display panel (ODP) button on the controller unit and
the expansion unit.
1
1 Operator display panel (ODP) button
To set the unit ID with the ODP button:
1. Turn on the unit.
2. Press and hold the ODP button until the first number on the seven-segment display starts
to blink.
Note: It can take up to three seconds for the number to blink. If the number does not
blink in this time, release the button and press it again. Make sure to press the button all
the way in.
3. Change the first number of the unit ID by repeatedly pressing the ODP button to advance
the number until you reach the desired number from 0 to 9.
The first number continues to blink.
4. Press and hold the ODP button until the second number on the digital display starts to
blink.
Note: It can take up to three seconds for the second number to blink. The first number on
the seven-segment display stops blinking.
5. Change the second number of the unit ID by repeatedly pressing the ODP button to
advance the number until you reach the desired number from 0 to 9.
The second number continues to blink.
6. Lock in the desired number, and exit the programming mode by pressing and holding the
ODP button until the second number stops blinking.
Note: It can take up to three seconds for the second number to stop blinking.