Data Sheet
• Storage range 10 to 90%
Acoustic noise
• Sound power (standby
operation)
65 dB max
• Sound pressure (normal
operation)
65 dBA max
12-bay expansion unit 12 x 2 TB (DSX‑N1D6X2‑12AT)
Electrical requirements—expansion unit
Parameter Low range High range
Nominal voltage 100 VAC 240 VAC
Frequency 50 to 60 Hz 50 to 60 Hz
Idle current 2.96 A 1.23 A
Maximum operating
current
3.03 A 1.26 A
Sequential drive
group spin up
4.23 A 1.76 A
Simultaneous drive
spin up
4.43 A 1.83 A
System rating plate
label
7.0 A 2.9 A
Power ratings—expansion unit
KVA 0.276
AC Watts 276
BTU/h 954
Note: for detailed information please see the NetApp E‑Series Storage
Systems Site Preparation Guide
System hardware specifications—expansion unit
Chassis DE1600 controller-drive tray
conforms to the 483 mm
(19.0 in) rack standard
Power supplies Dual redundant, hot pluggable
Maximum disk drives 12 x 2 TB, 3.5”, Nearline SAS
Maximum net capacity 20482 GB (RAID‑5 configured)
Integrated I/O 6 Gb SAS
Mechanical—expansion unit
Dimensions (H x W x D)
• Drive tray 86.4 x 482.6 x 552.5 mm
(3.4 x 19 x 21.75 in)
• Shipping carton 241.3 x 584.2 x 685.8 mm
(9.5 x 23 x 27 in)
Weight
• Maximum weight 27 kg (59.52 lb)
• Maximum shipping weight 31.75 kg (70.0 lb)
Space requirements
Front—cooling 760 mm (30 in) clearance in front
of the cabinet
Rear—cooling 610 mm (24 in) clearance behind
the cabinet
Front of chassis—maintenance 760 mm (30 in) clearance in front
of the cabinet
Rear of chassis—maintenance 610 mm (24 in) clearance behind
the cabinet
Environmental—expansion unit
Temperature
• Operating range (both
cabinet and subsystem)
+10 °C to +40 °C (+50 °F to
+104 °F)
• Maximum rate of change 10 °C (50 °F) per hour
• Storage range -10 °C to +50 °C (+14 °F to
+122 °F)
Relative humidity (non-condensing)
• Operating range (both
cabinet and subsystem)
20 to 80%
• Storage range 10 to 90%
Acoustic noise
• Sound power (standby
operation)
65 dB max
• Sound pressure (normal
operation)
68 dB max
60-bay expansion unit 60 x 3 TB (DSX‑N6D6X3‑60AT)
Electrical requirements—expansion unit
Parameter Low range High range
Nominal voltage 220 VAC 240 VAC
Frequency 50 to 60 Hz 50 to 60 Hz
Idle current 6.0 A 6.0 A
Maximum operating
current
7.56 A 7.56 A
Power ratings—expansion unit
KVA 1.268
AC Watts 1222
BTU/h 4180
Note: for detailed information please see the NetApp E‑Series Storage
Systems Site Preparation Guide
6 | DSA E-Series 2TB (E2700)