User guide

DS7446KP | User Guide | 3.0 Keypad Overview
Bosch Security Systems | 12/04 | 4998149924B 9
Table 2: System Status Indicators
Indicator State Description
On Steady Area is armed Perimeter Only or Partial On with Entry
Delay.
Slow Flash Area is armed Perimeter Only or Partial On without
Entry Delay.
Perim
Off Area is not armed Perimeter Only or Partial On.
On Steady No trouble conditions exist.
Fast Flash The area is in a test mode (System Test or Walk
Test), or the area is in the last 5 min of Walk Test.
Power
Slow Flash
A system or zone trouble exists.
Keypad moved from its home area using
[#][5][0] (Move to Area) command.
On Steady Area is armed All On, Perimeter Only, or Partial On
with Entry Delay.
Slow Flash Area is armed All On, Perimeter Only, or Partial On
without Entry Delay.
Armed
Off System is turned off.
On Steady The exit timer is running.
A command is active.
Fast Flash A PIN entry is required.
The entry timer is running.
Cmd
Slow Flash Another keypad in the same area is busy.
Refer to Figure 1 on page 7 for the location of the system status LEDs.