User guide

DS7446KP | User Guide | 3.0 Keypad Overview
8 Bosch Security Systems | 12/04 | 4998149924B
Depending on your system’s programming, your keypad might display an
area icon below the second line of text.
Table 1: Area Icon Functions
State Function
On Steady A user is operating the keypad outside of its home area using
the [#][5][0] (Move to Area) command. Refer to Section 11.5
Move to Area on page 32 for more information.
The area is armed, but not in alarm.
Fast Flash The area is in alarm.
Slow Flash A zone trouble condition exists.
A zone is bypassed in the area.
Off The area is disarmed.
No alarm or trouble conditions exist.
No zones are bypassed.
Area icon function is disabled in system programming
Refer to Figure 1 on page 7 for the location of the area icons.