Installation manual
Bosch Security Systems 
Divar - Easy | Installation Manual | Hardware setup EN | 4-4
Keyboard connection 
The keyboard input connector is used to connect an external keyboard to the 
unit. Connect the keyboard to the KBD IN connector. 
For short distances (up to 30m), standard 6-core telecom flat cable can be used 
to supply power and signal connections for the keyboard.
For distances over 30m between keyboard and Divar, the Keyboard Extension 
Kit (LTC 8557) must be used. This kit provides junction boxes, cables and the 
appropriate power supply for the external keyboards. The recommended cable 
type is Belden 9841 or equivalent.
Specifications
Communicaton protocol: RS485
Maximum signal voltage:  ± 12V 
Power supply: 11 - 12.6V, maximum 400mA
Maximum cable length:  1.5 kilometers 
Cable type: black (cross-over) cable (supplied with keyboard)
Termination: 390 Ohm terminator 
Keyboard In - RJ11 socket (KBD IN)
Pin no. Signal
1 +12 V DC (11V Min to 12.6V Max, 400mA Max)
2 System ground
3 Keyboard plus line 
4 Keyboard minus line
5 System ground
6 System ground
61