Technical data
11
• DOK-DIAX02-DDC01******-PRJ1-EN-E1,44 • 01.97
2. Technical Data/Ambient Conditions
2. Technical Data / Ambient Conditions
2.1. Data Sheet
Designation
Power section
3x 220 V (+15%/-10%) or
Input voltage U(N) (V) 3x 230 V (+10%/-15%)
Frequency f(N) (Hz) 50 ... 60 Hz
Peak current I(peak) (A) 50 100 200
Short-term curent for I(S6-100s) (A) 50 70 90
50 % at100 s duty cycle time
Continuous current (average) I(cont) (A) 25 35 45
Pulse frequency (PWM-frequency) f(T) (kHz) 8 4
Required connected load S(An) (kVA) Depends on motor/servo drive combination - see selection lists
Power requirement S(An) (kVA) 6 18 22.5
with maximum drive load
Short term mechanical operating P(S6-100s) (kW) 8 12 15
load for 50 % at100 s
duty cycle time, approx.
Continuous mechanical load, P(mech) (kW) 4 6 7.5
average
Usable mechanical peak load, P(mSp) (kW) 8.5 17 33
approx.
Power loss at maximum device P(V) (W) 500
load without bleeder power loss
Continuous bleeder power P(BD) (kW) 0,25 0.25 0.25
Peak bleeder power P(BM) (kW) 10 20 40
Maximum regenerated power W(max) (kWs) 5 10 20
Weight of basic unit m (kg) 21 22 22
Environmental conditions
Permissible ambient temperature T(amb)
o
C + 5 ... + 45
o
C
for rated specifications
Maximum ambient temperature T(m.amb)
o
C + 55
o
C
for derated specifications
Storage and shipping temp. T(L)
o
C - 30 ... + 85
o
C
Maximum installation elevation 1000 meters above sea level
without derating
Permissible relative humidity max. 95 %
Permissible absolute humidity 25 g water / m
3
air
Degree of contamination - non-conductive dirt contamination
- no condensate
Protection category IP 65 as per EN 60 529 ( IEC 529 )
DDC 1.2-N100A
DDC 1.2-N200A
DDC 1.2-N050C
Fig. 2.1: Technical data - DDC 1.2