Specifications
ISW-D8125CW-V2 | Installation and Operation Guide | Installation
6 Bosch Security Systems, Inc. | 8/11 | F01U161691-05
4. Connect the wiring (refer to Figure 6 on page 7, or
Figure 7 on page 8) to the commercial wireless
interface module and mount the cover unit to the
base.
Figure 5: ISW-D8125CW-V2 Mounting Options
1
1
2
2
3
1 - Four-screw mounting holes
(for mounting on an electrical box)
2 Two-screw mounting holes
(for mounting on an electrical box or in control
panel enclosure)
3 Wire routing openings
2.3 Wiring the Commercial Wireless
Interface Module to the Control
Panel and EN4200 Serial Receiver
Disconnect all power to the control panel
and to the commercial wireless interface
module before starting any work with the
internal components.
For UL Listed installations, install the
commercial wireless interface module
within 20 ft (6 m) of, and within the same
room as, the EN4200 Serial Receiver.
The maximum distance from the control
panel to the commercial wireless interface
module cannot exceed 5 ft
(1.5 m).
For best transmitter reception results, place the
EN4200 Serial Receiver in a central location among
the transmitters. If transmitters are too far away for the
receiver to pick up the transmission, install an
ISW-EN5040-T Commercial Wireless RF Repeater.
Certain installation configurations may require a
second EN4200 Receiver.
Refer to Figure 6 on page 7, and Figure 7 on page 8, for
proper wiring connections.