User manual
Table Of Contents
- Index
- 1 Key to symbols and safety instructions
- 1.1 Key to symbols
- 1.2 Safety information
- 2 Standard delivery
- 3 Appliance details
- 4 Installation instructions
- 4.1 Tools required
- 4.2 Location requirements
- 4.3 Secure the appliance
- 4.4 Water piping
- 4.4.1 Inlet - Outlet connections
- 4.4.2 Dielectric joint (not supplied with the appliance)
- 4.4.3 Condensate Drain Tubes (not supplied with the appliance)
- 4.4.4 TPR Valve (supplied with the appliance)
- 4.4.5 Thermal expansion tank (not supplied with the appliance)
- 4.4.6 Temperature mixing device (not supplied with the appliance)
- 4.4.7 Pressure limiting valve (not supplied with the appliance)
- 4.4.8 Expansion control valve (not supplied with the appliance)
- 4.5 Electric requirements
- 4.6 Installation configurations
- 4.7 Insulation blanket
- 4.8 Fill the water storage tank
- 4.9 Installation checklist
- 4.10 What to expect for “normal startup”
- 4.11 Off-peak compatibility
- 5 Operation Instructions
- 5.1 Safety warnings
- 5.2 Working display
- 5.3 Working modes
- 5.4 „Operating“ menu
- 5.5 Temperature set point
- 5.6 „Main“ menu
- Accessing the „Main“ menu
- 5.6.1 „Mode“ function - heating modes
- 5.6.2 „Prog“ function - Timetable operation programming
- 5.6.3 Silent Mode programming - „Sil“ function
- 5.6.4 „Leg“ function - automatic thermal disinfection
- 5.6.5 „Set“ function - adjustments
- 5.6.6 „Purg“ function - purge
- 5.6.7 „Info“ function - information
- 5.7 Troubleshooting
- 5.8 Factory configurations
- 5.9 Selecting the temperature units - „C“ or „F“
- 5.10 Setting the time and day of the week
- 5.11 Controls
- 6 Maintenance and repair
- 6.1 Periodic Inspection
- 6.2 Temperature and pressure relief valve (PTR Valve)
- 6.3 Flushing tank
- 6.4 Draining the Water Heater
- 6.5 Vacation and Extended Shutdown
- 6.6 Clearing the Condensation Drain Tubes
- 6.7 Refrigerant circuit
- 6.8 Anode Rod servicing
- 6.9 Checking/replacing the magnesium anode
- 6.10 Service menu
- 7 Display
- 8 Electrical diagram
- 9 Environmental protection
- 10 Warranty details

6 720 801 244 (2013/08)Compress 3000 DW FO
Appliance details | 9
3.3 Specification tables
Model HP 270-1E 0 FOV/S...
Running modes Heat Pump Only Mode
Running ambient air temp. °C +3 °C/+40 °C
Outlet Water Temp. °C 60 °C - 65 °C
Minimum Inlet Water Temp. °C 3 °C
Maximum Inlet Water Temp. °C 70 °C
Power supply Ph-V-Hz 1ph / 230V-240V / 50 Hz
IP rating IP X4
Storage size ltr 270
Water heating Heating capacity
1)
kW 1.5
Max. input
1)
kW 0.6
COP
1)
-3.3
Max. current
1)
A2.5
Unit Dimension (D×H) mm 670 x 1840
Packing (W×H×D)
mm 770 x 770 x 2050
Net/gross weight
kg 130
Sound pressure level at 2 m dB (A) 43
Refrigerant type/Mass kg R134a / 0.375
Max. refrigerant circuit pressure kPa 2700
PTR valve setting
2)
kPa 1000
Throttling type Thermal expansion valves
System protection High pressure switch, Temperature limiter
Air flow m
3
/h 350
Compressor Model WHP01900
Type
Rotary
Brand
Highly
Input
W700
Fan motor Model W1G230EB
Brand
EBM Papst
Input
W28
Speed
r/min 1500
Water connections Water inlet ¾ BSP inch
Water outlet
¾ BSP inch
Max. water working
kPa 1000
PTR valve joint
½ BSP inch
Max inlet pressure
kPa 800
Heat exchanger
Double wall plate heat exchanger
E-heater Rated power input at 240 V kW 1.8
Rated current at 240 V
A7.8
Table 2
1) EN255-3, water inlet 15 °C, air at 15 °C
2) PTR valve power capacity: 10 kW