User manual
Table Of Contents
- Index
- 1 Key to symbols and safety instructions
- 1.1 Key to symbols
- 1.2 Safety information
- 2 Standard delivery
- 3 Appliance details
- 4 Installation instructions
- 4.1 Tools required
- 4.2 Location requirements
- 4.3 Secure the appliance
- 4.4 Water piping
- 4.4.1 Inlet - Outlet connections
- 4.4.2 Dielectric joint (not supplied with the appliance)
- 4.4.3 Condensate Drain Tubes (not supplied with the appliance)
- 4.4.4 TPR Valve (supplied with the appliance)
- 4.4.5 Thermal expansion tank (not supplied with the appliance)
- 4.4.6 Temperature mixing device (not supplied with the appliance)
- 4.4.7 Pressure limiting valve (not supplied with the appliance)
- 4.4.8 Expansion control valve (not supplied with the appliance)
- 4.5 Electric requirements
- 4.6 Installation configurations
- 4.7 Insulation blanket
- 4.8 Fill the water storage tank
- 4.9 Installation checklist
- 4.10 What to expect for “normal startup”
- 4.11 Off-peak compatibility
- 5 Operation Instructions
- 5.1 Safety warnings
- 5.2 Working display
- 5.3 Working modes
- 5.4 „Operating“ menu
- 5.5 Temperature set point
- 5.6 „Main“ menu
- Accessing the „Main“ menu
- 5.6.1 „Mode“ function - heating modes
- 5.6.2 „Prog“ function - Timetable operation programming
- 5.6.3 Silent Mode programming - „Sil“ function
- 5.6.4 „Leg“ function - automatic thermal disinfection
- 5.6.5 „Set“ function - adjustments
- 5.6.6 „Purg“ function - purge
- 5.6.7 „Info“ function - information
- 5.7 Troubleshooting
- 5.8 Factory configurations
- 5.9 Selecting the temperature units - „C“ or „F“
- 5.10 Setting the time and day of the week
- 5.11 Controls
- 6 Maintenance and repair
- 6.1 Periodic Inspection
- 6.2 Temperature and pressure relief valve (PTR Valve)
- 6.3 Flushing tank
- 6.4 Draining the Water Heater
- 6.5 Vacation and Extended Shutdown
- 6.6 Clearing the Condensation Drain Tubes
- 6.7 Refrigerant circuit
- 6.8 Anode Rod servicing
- 6.9 Checking/replacing the magnesium anode
- 6.10 Service menu
- 7 Display
- 8 Electrical diagram
- 9 Environmental protection
- 10 Warranty details

6 720 801 244 (2013/08)Compress 3000 DW FO
Appliance details | 7
3 Appliance details
3.1 Overview
Fig. 3 Appliance overview
3.2 Features and safety devices
Easy to operate and environmentally friendly
The heat pump has user interface with easy use menu keys for
ease of programming. The heat pump is also environmental
friendly as it transfers heat from the surrounding area into the
water.
Heating capacity
The unit absorbs ambient energy and releases the heat into the
water stored in the tank. If the ambient temperature is low, the
heating capacity of the heat pump will be reduced, but you can
still rely on the electric element for backup.
Thermal Cut Out (TCOs)
The water heater is equipped with one thermal cut out (TCO)
located above the heating element, in contact with the tank
surface. If for any reason the water temperature becomes
excessively high, the thermal cut-out (TCO) cuts the power
circuit to the heating element. Once activated, the TCO must be
reset manually. Resetting of the temperature limiting control
should be done by a qualified service technician.
Air inletAir outlet
User
interface
User
interface
cap
Tank
6720801244-03.1V
CAUTION:
The cause of the high temperature condition
must be investigated by a qualified service
technician and corrective action must be
taken before placing the water heater in
service again.