Technical data
CCS 900 Ultro Appendix | en 43
Bosch Security Systems B.V. Installation and Operating Manual IOM_CCS900 | V1.0 | 2010.06
10.2 Mounting Instructions
The CU can be attached in three different ways:
– In a 19" rack making use of the 19" rack mounting set LBB 3311/00. Place a blank 1HU
panel above the CU to have sufficient space for cable connections.
– Mounted into a table using the flush mount bracket.
– On a table. Therefore drill four holes in the table and fasten the CU with four M3 screws
(B).
The Delegate and Chairman Units can only be attached on a table. Therefore drill two holes in
the table and fasten the unit with two self tapping M3 screws (A).
Figure 10.3 Mounting into a table
Figure 10.4 Mounting on a table
NOTICE!
When the device is attached to a flat surface it no longer conforms to the UL/CSA approval.